32
Inspections
The machine must be inspected according to the “Guidelines for Liquid Spray
Devices” at least once every 12 months by a qualified person, to ensure that contin-
ued safe operation is guarateed. The results of the inspection are to be recorded in
writing. This may be done in any form.
Accident prevention
The machine is designed for accidents to be impossible if used correctly.
The operator is to be notified of the risk of injury from hot machine parts and the
high pressure water jet. The “Guidelines for Liquid Spray Devices” must be complied
with. (see page 14 and 15)
Oil change:
Check the oil level at the oil sight glass prior to each use.
(Ensure horizontal position!) The oil level should be at the middle of
the sight glass. With high atmospheric humidity and temperature
fluctuation there may be condensation (oil has a greyish colour);
Then the oil must be changed.
First oil change after approx 50 hours of operation. Thereafter, no more oil change is
required for the lifetime of the equipment. If it becomes necessary during repairs, or
because the oil has a greyish colour to perform an oil change, then the oil sight
glass should be opened and the oil emptied into a container. The oil must be caught
in a container and disposed of in a responsible, legal manner.
New oil: 0.25 l - Motor oil: W 15/40
Oil leak
In the event of an oil leak contact customer service (dealer) immediately. (damage to
environment or transmission)
General rules
Содержание HD 10/120
Страница 22: ...22 Complete assembly...
Страница 24: ...24 Motor...
Страница 26: ...26 Transmission...
Страница 28: ...28 Valve housing...
Страница 34: ...34 Notes...
Страница 35: ...35 Notes...
Страница 36: ...Reprint only allowed with the authorization of As date of 06 07 2005 Order n 30 760 1 R...