Setting the DIP-Switches
DIP-switches 1, 2 and 3 are set to ON by default and DIP-switch 4 is always set to OFF.
DIP-switch changes take effect immediately.
#
Feature
Dip-Switch Settings
1
Switching Mode
OFF
– Manual mode.
ON
–Auto-switching mode.
2
Auto-switching Mode
OFF
– Priority switching mode: the device
switches the source with the
highest priority to the output.
ON
– Last connected switching mode: the last detected active source is
auto-switched to the output.
3
EDID lock
Off
– EDID Locked.
On
– EDID parameters are passed-through.
4
Reserved for Factory Use It is mandatory to keep set to OFF.
For optimum range and performance use the recommended Kramer cables available at
www.kramerav.com/product/WP-211X
Grounding the
WP-211X
(Optional)
1. Connect the ring tongue terminal to the building grounding point wire (a green-yellow, AWG#18 (0.82mm
2
) wire,
crimped with a proper hand-tool is recommended).
2. Insert the M3x6 screw through the toothed lock washers and the tongue terminal in the order shown above.
3. Insert the M3x6 screw (with the two toothed lock washers and ring tongue terminal) into the grounding screw hole
and tighten the screw.
Step 5: Connect the power
Connect the 12V power adapter to the device and plug the power supply into the mains electricity.
Safety Instructions
Caution:
•
For products with relay terminals and GPI\O ports, please refer to the permitted rating for an external connection, located next to the terminal or in the User Manual.
•
There are no operator serviceable parts inside the unit.
Warning:
•
Use only the power cord that is supplied with the unit.
•
Disconnect the power and unplug the unit from the wall before installing.
•
Do not open the unit. High voltages can cause electrical shock! Servicing by qualified personnel only.
•
To ensure continuous risk protection, replace fuses only according to the rating specified on the product label which located on the bottom of the unit.