7.  Select the output from which the EDID is acquired (for example, OUT 4).  

8.  Press the IN 3 button.  

The IN 3 button stops flashing. 

9.  Press the input buttons to which you want to copy the EDID (for example, IN 

1 and IN 3). 

10.  Make sure that the relevant input numbers flash on the display. 

11.  Press the EDID button. 

The process is complete when the display returns to normal. 

6.2.3 

Acquiring the Default EDID 

To store the default EDID on a selected input (for example, Input 2): 

1.  Press the EDID and STO buttons simultaneously and hold them for 3 

seconds. 

Both buttons flash.  

2.  Press the input (for example, Input 2) to which the EDID is to be copied. 

The selected input number flashes on the display. 

3.  Press the OFF button until "0" (zero) appears on the display.  

4.  Press the EDID button. 

The default EDID is stored on the selected input when the display returns to 

normal. 

6.3 

Storing and Recalling a Preset  

You can use the STO and RCL buttons to store up to 12 setups and then recall 

them using the OUT (1-4) and IN (5 -12) SELECTOR buttons (se

Figure 4

).  

 

Figure 4: Store-Recall Button Configuration  

im Vertrieb von            CAMBOARD Electronics

www.camboard.de

Tel. 07131 911201
Fax 07131 911203

[email protected]

Содержание VS-84HN

Страница 1: ...RAMER ELECTRONICS LTD USER MANUAL MODEL VS 84HN 8x4 HDMI Matrix Switcher P N 2900 300157 Rev 7 im Vertrieb von CAMBOARD Electronics www camboard de Tel 07131 911201 Fax 07131 911203 ce info camboard d...

Страница 2: ...im Vertrieb von CAMBOARD Electronics www camboard de Tel 07131 911201 Fax 07131 911203 ce info camboard de...

Страница 3: ...and Protocol 3000 15 6 6 Connecting via RS 232 15 6 7 Connecting via Ethernet 15 6 8 Upgrading the Firmware 17 7 Technical Specifications 18 8 Default Communication Parameters 19 9 Default EDID 20 10...

Страница 4: ...on GROUP 1 Distribution Amplifiers GROUP 2 Switchers and Routers GROUP 3 Control Systems GROUP 4 Format Standards Converters GROUP 5 Range Extenders and Repeaters GROUP 6 Specialty AV Products GROUP 7...

Страница 5: ...cables we recommend Kramer high performance high resolution cables to avoid interference deterioration in signal quality due to poor matching and elevated noise levels often associated with low quali...

Страница 6: ...002 96 EC aims to reduce the amount of WEEE sent for disposal to landfill or incineration by requiring it to be collected and recycled To comply with the WEEE Directive Kramer Electronics has made arr...

Страница 7: ...nsures Plug and Play operation for HDMI systems Kramer reKlocking Equalization Technology that rebuilds the digital signal to travel longer distances A lock button to prevent unwanted tampering with t...

Страница 8: ...OUT 1 to 4 Press to select an output to switch followed by an input also used for storing machine setups see Section 6 3 7 IN 1 to 8 Press to select the input to switch after selecting an output also...

Страница 9: ...Gateway 192 168 1 1 Depress the button while powering on the device The device powers up with the factory default IP parameters 18 REMOTE IR Opening Connect to an external IR receiver for controlling...

Страница 10: ...This distance can be extended to up to 60 meters when used with three extension cables Model C A35M A35F 50 Before using the external IR receiver be sure to arrange for your Kramer dealer to insert th...

Страница 11: ...nstalling in a Rack 4 Installing in a Rack This section provides instructions for rack mounting the unit im Vertrieb von CAMBOARD Electronics www camboard de Tel 07131 911201 Fax 07131 911203 ce info...

Страница 12: ...ources for example DVD players to the IN HDMI connectors You do not have to connect all the sources 2 Connect the four OUT HDMI connectors to up to four HDMI acceptors for example LCD displays with bu...

Страница 13: ...Connecting the VS 84HN 8x4 HDMI Matrix Switcher Figure 3 Connecting the VS 84HN 8x4 HDMI Matrix Switcher im Vertrieb von CAMBOARD Electronics www camboard de Tel 07131 911201 Fax 07131 911203 ce info...

Страница 14: ...the firmware see Section 6 8 6 1 Switching an Input to an Output To switch an input to an output Press an output button followed by an input button to switch the selected input to the selected output...

Страница 15: ...flashing 6 2 2 Acquiring the EDID from Different Outputs to Different Inputs To acquire the EDID from several outputs for example OUT 1 to IN 1 and OUT 4 to IN 3 1 Connect the display devices to the...

Страница 16: ...ut 2 1 Press the EDID and STO buttons simultaneously and hold them for 3 seconds Both buttons flash 2 Press the input for example Input 2 to which the EDID is to be copied The selected input number fl...

Страница 17: ...times out To recall a preset for example preset 10 1 Press the RCL button The RCL button flashes 2 Press the relevant OUT or IN button that stored the preset for example IN 6 preset 10 3 Press the RC...

Страница 18: ...onnect the RS 232 9 pin D sub on the rear panel of the VS 84HN via a 9 wire straight cable only pin 2 to pin 2 pin 3 to pin 3 and pin 5 to pin 5 need to be connected to the RS 232 9 pin D sub port on...

Страница 19: ...al Area Connection Properties 4 Select Properties The Local Area Connection Properties window appears 5 Select the Internet Protocol TCP IP and click the Properties Button see Figure 5 Figure 5 Local...

Страница 20: ...connect the Ethernet port of the VS 84HN to the Ethernet port on a network hub or network router via a straight through cable with RJ 45 connectors 6 8 Upgrading the Firmware For instructions on upgra...

Страница 21: ...ons infrared remote control transmitter RS 232 Ethernet OPERATING TEMPERATURE 0 to 40 C 32 to 104 F STORAGE TEMPERATURE 40 to 70 C 40 to 158 F HUMIDITY 10 to 90 RHL non condensing DIMENSIONS 19 x 7 x...

Страница 22: ...1 0x01 0x81 0x81 0x81 Example Output 1 to Input 1 AV 1 1 CR Switching Protocol P2000 P3000 P3000 P2000 Command 0x38 0x80 0x83 0x81 Command P2000 CR Front Panel Press and hold Output 1 and Output 3 si...

Страница 23: ...nge 31 94kHz Vertical scan range 50 85Hz Video bandwidth 170MHz CVT standard Not supported GTF standard Not supported Additional descriptors None Preferred timing Yes Native preferred timing 1280x720p...

Страница 24: ...0Hz 16 9 Modeline 1920x1080 74 250 1920 2448 2492 2640 1080 1084 1094 1124 interlace hsync vsync Detailed timing 4 1280x720p at 60Hz 16 9 Modeline 1280x720 74 250 1280 1390 1430 1650 720 725 730 750 h...

Страница 25: ...physical address 1 0 0 0 Maximum TMDS clock 165MHz Report information Date generated 08 03 2011 Software revision 2 52 0 857 Data source Real time 0x0031 Operating system 5 1 2600 2 Service Pack 3 im...

Страница 26: ...s set as the input number to be switched If switching is done using the machine s front panel these bits are set with the INPUT NUMBER switched For other operations these bits are defined according to...

Страница 27: ...performs the instruction and if the instruction is performed due to a keystroke operation on the front panel then these codes are sent For example if the HEX code 01 85 88 83 was sent from the PC the...

Страница 28: ...chine which is being addressed not to the system For example if six 16X16 matrices are configured to make a 48X32 system 48 inputs 32 outputs the reply to the HEX code 3E 82 81 82 ie request the numbe...

Страница 29: ...Delimiter Command SP Parameter_1 Parameter_2 CR 11 1 1 2 Command String Formal syntax with commands concatenation and addressing Start Address Body Delimiter device_id Command_1 Parameter1_1 Parameter...

Страница 30: ...more than one command Commands are separated by a pipe character Message starting character For host command query For device response Device ID Optional for K NET K NET Device ID followed by Query s...

Страница 31: ...s Some commands have short name syntax in addition to long name syntax to allow faster typing The response is always in long syntax 11 1 6 Chaining Commands Multiple commands can be chained in the sam...

Страница 32: ...et count End User LDEDID Load EDID data User SW Internal LOCK FP LCK Lock front panel Administrator LOCK FP LCK Read Lock front panel End User MODEL Read device model End User P2000 Switch to protocol...

Страница 33: ...im Vertrieb von CAMBOARD Electronics www camboard de Tel 07131 911201 Fax 07131 911203 ce info camboard de...

Страница 34: ...be found We welcome your questions comments and feedback Web site www kramerelectronics com E mail info kramerel com P N 2900 300157 Rev 7 SAFETY WARNING Disconnect the unit from the power supply bef...

Отзывы: