![Kramer VS-81SP Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/kramer/vs-81sp/vs-81sp_user-manual_2002345028.webp)
Hex Table
25
25
10
Hex Table
Table 6
lists the Hex values (which the protocol in section
11
describes in
more detail) for the
VS-81SP
:
Table 6: VS-81SP Hex Table
Input#
OUT
IN 1
01 81 81 81
IN 2
01 82 81 81
IN 3
01 83 81 81
IN 4
01 84 81 81
IN 5
01 85 81 81
IN 6
01 86 81 81
IN 7
01 87 81 81
IN 8
01 88 81 81
11
Kramer Protocol 2000
The
VS-81SP
is compatible with Kramer’s Protocol 2000, version 0.50.
This RS-232/RS-485 communication protocol uses four bytes of
information as defined below. For RS-232, a null-modem connection
between the machine and controller is used. The default data rate is 9600
baud, with no parity, 8 data bits, and 1 stop bit.
Note
: Compatibility with Kramer’s Protocol 2000 does not mean that a
machine uses all of the commands below. Each machine uses a sub-set of
Protocol 2000, according to its needs.
Table 7: Protocol Definitions
MSB
LSB
DESTINATION
INSTRUCTION
0
D
N5
N4
N3
N2
N1
N0
7
6
5
4
3
2
1
0
1st byte
INPUT
1
I6
I5
I4
I3
I2
I1
I0
7
6
5
4
3
2
1
0
2nd byte
OUTPUT
1
O6
O5
O4
O3
O2
O1
O0
7
6
5
4
3
2
1
0
3rd byte
MACHINE NUMBER
1
OVR
X
M4
M3
M2
M1
M0
7
6
5
4
3
2
1
0
4th byte