VS-81HDxl - Protocol 2000
23
8.2
Instruction Codes
All the values in the table are decimal, unless otherwise stated
Instruction Codes for Protocol 2000
Instruction
Definition for Specific Instruction
Notes
#
Description
Input
Output
0
RESET VIDEO
0
0
1
1
SWITCH VIDEO
Set equal to video input that is
switched
(0 = disconnect)
Set equal to video output that is
switched
(0 = to all the outputs)
2, 15
5
REQUEST STATUS OF
A VIDEO OUTPUT
Set as SETUP #
Equal to output number whose
status is required
4, 3
16
ERROR / BUSY
For invalid / valid input (i.e.
OUTPUT byte = 4 or OUTPUT byte
= 5),
this byte is set as the input #;
For invalid / valid output (i.e.
OUTPUT byte=7 or OUTPUT
byte=8), this byte is set as the
output#
0
– Error
1
– Invalid instruction
2
– Out of range
3
– Machine busy
4
– Invalid input
5
– Valid input
6
– RX buffer overflow
7
– Invalid output
8
– Valid output
9
– Valid EDID
9, 25
30
LOCK FRONT PANEL
Unlock panel
Lock panel
0
2
31
REQUEST WHETHER
PANEL IS LOCKED
0
0
16
61
IDENTIFY MACHINE
1
– Video machine name
2
– Audio machine name
3
– Video software version
4
– Audio software version
5
– RS-422 controller name
6
– RS-422 controller version
7
– Remote control name
8
– Remote software version
9
– Protocol 2000 revision
10
– Control data machine name
11
– Control data software version
For names:
0
– Request first 4 digits
1
– Request first suffix
2
– Request second suffix
3
– Request third suffix
10
– Request first prefix
11
– Request second prefix
12
– Request third prefix
For versions:
0
– main board
or the number of external board
13
62
DEFINE MACHINE
1
– Number of inputs
2
– Number of outputs
3
– Number of setups
1
– For video
2
– For audio
3
– For SDI
4
– For remote panel
5
– For RS-422 controller
6
– For control data
14
NOTES on the above table:
NOTE 1
– When the master switcher is reset, (e.g. when it is turned on), the reset code is sent to the PC. If this code is
sent to a switcher, it resets according to the present power-down settings.
NOTE 2
– These are bi-directional definitions. If the switcher receives the code, it performs the instruction. If the
instruction is performed (due to a keystroke operation on the front panel), then these codes are sent.
For example, if the PC sends HEX code:
01
85
88
83
then the switcher (machine 3) switches input 5 to output 8.
If the user switches input 1 to output 7 using the front panel buttons, the switcher sends HEX code:
41
81
87
83
to the PC.
When the PC sends one of the commands in this group to the switcher, if the instruction is valid, the switcher replies by
sending the same four bytes to the PC that it received (except for the first byte, where the DESTINATION bit is set high).
NOTE 3
– SETUP # 0 is the present setting. SETUP # 1 and higher are the settings saved in the switcher's memory,
(i.e. those used for Store and Recall).
NOTE 4
– The reply to a REQUEST instruction is as follows: the same instruction and INPUT codes that were sent are
returned, and the OUTPUT is assigned the value of the requested parameter. The replies to instructions 10 and 11 are
according to the definitions in instructions 7 and 8 respectively.
For example, if the present status of machine number 5 is breakaway setting, then the reply to HEX code:
0B
80
80
85
is HEX code:
4B
80
81
85
Содержание VS-81HDxl