58
VS-62DT - Kramer Protocol 3000 Commands
15.2.8 PRIO
Command Name
Permission
Transparency
Set:
–
–
–
Get
PRIO?
Administrator
Public
Description
Syntax
Set:
–
–
Get:
Get input priority
#PRIO?
␠
input_id
␍
Response
~nn@PRIO
␠
input_id,prio
␍␊
Parameters
input_id
-
window number setting new source
1
(Input 1)…
6
(Input 6)
prio
-
assigned priority
1
(max. priority),
6
(min. priority)
Response Triggers
After execution, response is sent to the comm port from which the Set/Get was received
After execution, response is sent to all comm ports if PRIO was set by any other external control device
(button press, device menu and similar)
Notes
The PRIO max value may vary for different devices
K-Config Example
Get the input priority Input 3:
“#PRIORITY? 3”,0x0D
15.2.9 SIGNAL?
Command Name
Permission
Transparency
Set:
-
-
-
Get
SIGNAL?
End User
Public
Description
Syntax
Set:
-
-
Get:
Get input signal lock status
#SIGNAL?
␠
inp_id
␍
Response
~nn@SIGNAL
␠
inp_id,status
␍␊
Parameters
inp_id
-
1
(Input 1)…
6
(Input 6)
status
- lock status according to signal validation -
0
(signal off),
1
(signal on)
Response Triggers
After execution, a response is sent to the comm port from which the Get was received
Response is sent after every change in input signal status ON to OFF, or OFF to ON
Notes
K-Config Example
Get the input signal lock status of HDMI In 2:
“#SIGNAL? 2”,0x0D