VS-44HDCP - Protocol 3000
29
29
Command -
DISPLAY?
Command Type - System
Command Name
Permission
Transparency
Set:
-
-
-
Get
DISPLAY?
End User
Public
Description
Syntax
Set:
-
-
Get:
Get output HPD status
#
DISPLAY?
␠
out_id
␍
Response
~ nn@
DISPLAY
␠
out_id,status
␍␊
Parameters
out_id -
output number
status
- HPD status according to signal validation
– 0: Signal or sink is not valid, 1: Signal or sink is
valid, 2: Sink and EDID is valid
Response Triggers
After execution, response is sent to the com port from which the Get was received
Response is sent after every change in output HPD status ON to OFF
Response is sent after every change in output HPD status OFF to ON and ALL parameters (new EDID,
etc.) are stable and valid
Command
–
FACTORY
Command Type
– System-mandatory
Command Name
Permission
Transparency
Set:
FACTORY
End User
-
Get:
-
-
-
Description
Syntax
Set:
Reset device to factory defaults configuration
#FACTORY
␍
Get :
-
-
Response
~
nn
@
BUILD-DATE
␠
date
␠
time
␍␊
Notes
This command deletes all user data from the device. The deletion can take some time.