VS-42HDCP - Protocol 3000
29
29
12.3
Kramer Protocol 3000
– Detailed Commands
This section describes the detailed commands list.
Command -
BUILD-DATE
Command Type - System-mandatory
Command Name
Permission
Transparency
Set:
-
-
-
Get:
BUILD-DATE?
End User
Public
Description
Syntax
Set:
Get device build date
#
BUILD-DATE
␍
Get:
-
-
Response
~nn@
BUILD-DATE
␠
date
␠
time
␍␊
Parameters
date
-
Format: YYYY/MM/DD where YYYY = Year, MM = Month, DD = Day
time
-
Format: hh:mm:ss where hh = hours, mm = minutes, ss = seconds
Command -
CPEDID
Command Type - System
Command Name
Permission
Transparency
Set:
CPEDID
End User
Public
Get:
-
-
-
Description
Syntax
Set:
Copy EDID data from the output to
the input EEPROM
#
CPEDID
␠
output_id, input_id
␍
Get:
-
-
Response
~nn@
CPEDID
␠
output_id, input_id
␍␊
Parameters
output_id
–
Video output id
input_id
–
Video input id
Response Triggers
Response is sent to the com port from which the Set was received (before execution)
Notes
Destination bitmap size depends on device properties (for 64 inputs it is a 64-bit word)
Example: bitmap 0x0013 means inputs 1,2 and 5 are loaded with the new EDID