ADDENDUM:
RC-3000 / VS-3000
P/N: 2900-0030001
A1
The VS 3000 is renamed the RC 3000
.
Section A
includes the RS 485 PINOUT.
Section B
is
relevant only to FIRMWARE VERSION 3016, when working with the 1616 and 162 Series switchers.
A). The RS-485 PINOUT is as follows:
B).
This part of the addendum applies ONLY to VS-3000
FIRMWARE VERSION 3016
,
which is applicable
ONLY when working with the 1616 and 162 Series switchers. The
following sections are amended: 7.4, 7.5, 8.2.1, 8.2.3, 8.2.4, and 8.3.
The
VS-3000
user manual applies to
VS-3000
firmware versions 1.2
,
1.3
,
and 1.4
.
Sections 7.4, 7.5, 8.2.3 and 8.2.4
Sections 7.4, 7.5, 8.2.3 and 8.2.4
do not apply.
Section 8.2.1
Text in section 8.2.1 “
Key Assignments
”, “
DIRECTION keys
” is substituted by the following text:
In the
REGULAR MODE
, scroll between the switchers
1
, using the UP and DOWN buttons. The LEFT
and the RIGHT buttons have no effect.
The VS-3000
FIRMWARE VERSION 3016
automatically detects the switcher and its
characteristics, including the Machine #.
The IN / OUT connections appear in the LCD MATRIX display and the relevant Machine # appears in
the LCD STATUS display
2
.
In the
MENU MODE
, navigate between commands using the LEFT and RIGHT buttons. The UP and
DOWN buttons have no effect.
Text in section 8.2.1 “
Key Assignments
”, “
DIRECTION keys
”, “
ENTER
” is substituted by the
following text:
In the
REGULAR MODE
, press the ENTER button to confirm an action (in the Confirm mode) and
press and hold the ENTER button
to access the
MENU MODE
.
In the
MENU MODE
, press the ENTER button to move to the next MENU.
Sections 8.3
Section 8.3 “
MENU Functions
” is substituted by the following text:
CONTROLLER LOCK/UNLOCK: Locking prevents accidentally changing the settings. To lock the
VS-3000
:
1.
Press and hold the ENTER button to access the MENU MODE command screen. The MATRIX
Display shows the message:
Controller LOCK / UNLOCK
< - Lock Unlock - >
2.
Press the
LEFT
button. The panel locks and the MATRIX Display momentarily shows the
message:
PANEL is LOCKED
Unlocking releases the protection mechanism. To unlock the
VS-3000
:
1.
Press and hold the ENTER button.
2.
Press the
RIGHT
button.
The panel unlocks and the MATRIX Display momentarily shows the message:
PANEL is UNLOCKED
1 That is, switchers in the series of 16x16 matrix switchers that include VS-1616V, VS-1616A, VS-1616AD, VS-1616SDI,
VS-162V, and/or VS-162AV
2 A “No Communication. Offline” error message will display if a switcher is unconnected or its power is off