background image

 

 

 

www.KramerAV.com  
[email protected] 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P/N: 

2900- 300581

 

Rev: 

3

 

 

 

 

 

SAFETY WARNING 

Disconnect the unit from the power supply before opening and servicing 

 

 

 

For the latest information on our products and a list of Kramer distributors, visit our Web site where 
updates to this user manual may be found. 

We welcome your questions, comments, and feedback. 

Содержание VS-211H2

Страница 1: ...P N 2900 300581 Rev 3 www kramerAV com USER MANUAL MODEL VS 211H2 Automatic HDMI Standby Switcher...

Страница 2: ...Introduction 1 Getting Started 1 Overview 3 Defining the VS 211H2 Automatic HDMI Standby Switcher 4 Connecting the VS 211H2 5 Connecting the REMOTE Terminal Block Connector 6 Setting the VS 211H2 DIP...

Страница 3: ...lable where appropriate Achieving the Best Performance Use only good quality connection cables we recommend Kramer high performance high resolution cables to avoid interference deterioration in signal...

Страница 4: ...g it to be collected and recycled To comply with the WEEE Directive Kramer Electronics has made arrangements with the European Advanced Recycling Network EARN and will cover any costs of treatment rec...

Страница 5: ...data rate of 17 82Gbps 5 94Gbps per data channel Maximum resolution 4K 60 UHD 4 4 4 HDTV compatible HDR10 HDCP 2 2 does not support conversion to HDCP 1 4 and HDMI 2 0 compliant 3D pass though HDMI su...

Страница 6: ...ight when power is supplied to the unit 5 INPUT 1 Connector Connects to HDMI source 1 6 INPUT 2 Connector Connects to HDMI source 2 7 OUTPUT Connector Connects to the HDMI acceptor 8 LAST CONN PRIORIT...

Страница 7: ...2 do the following 1 Connect the INPUT 1 connector to HDMI source 1 for example a Blu ray player 2 Connect the INPUT 2 connector to HDMI source 2 for example a laptop computer graphics source 4K 60 U...

Страница 8: ...e input source 2 momentarily connect REMOTE IN2 to PIN G ground Do not connect both the REMOTE IN1 and the REMOTE IN2 to PIN G simultaneously Figure 3 REMOTE Terminal Block Connector The contact closu...

Страница 9: ...switching Last Connected Setting DIP 1 is Set to OFF Up In this switching mode whenever a source is connected to an input which until then did not have a valid source connected to it that input is swi...

Страница 10: ...ntal Conditions Operating Temperature 0 to 40 C 32 to 104 F Storage Temperature 40 to 70 C 40 to 158 F Humidity 10 to 90 RHL non condensing Regulatory Compliance Safety CE FCC UL Environmental RoHs WE...

Страница 11: ...y you If this product is returned uninsured you assume all risks of loss or damage during shipment Kramer Electronics will not be responsible for any costs related to the removal or re installation of...

Страница 12: ...RNING Disconnect the unit from the power supply before opening andservicing For the latest information on our products and a list of Kramer distributors visit our Web site where updates to this user m...

Отзывы: