Kramer VS-121HC Скачать руководство пользователя страница 30

Kramer Protocol 2000 

 

27 

Table 9: Instruction Codes

 

INSTRUCTION 

DEFINITION FOR SPECIFIC INSTRUCTION 

NOTE 

DESCRIPTION 

INPUT 

OUTPUT 

 

RESET VIDEO 

SWITCH VIDEO 

Set equal to video input which is to 

be switched 

0-12: 
0: Disconnect 
1–4: CV group 
5–8: SV group 
9–12: Component group 

Set equal to video output 

which is to be switched 

REQUEST STATUS OF A VIDEO 

OUTPUT 

Set as SETUP # 

OUTPUT # 

3, 4 

30 

LOCK FRONT PANEL 

0: Panel unlocked 
1: Panel locked 

31 

REQUEST WHETHER PANEL IS 

LOCKED 

16 

55 

REPLY ON 

0 - Off 
1 - On 

26 

57 

SET AUTO SAVE 

I3: No save 
I4: Autosave 

12, 2 

61 

IDENTIFY MACHINE 

1: Video machine name 
3: Video software version 

0: Request first 4 digits 
1: Request first suffix 
10: Request first prefix 

13 

62 

DEFINE MACHINE 

1: Number of inputs 
2: Number of outputs 

1  

14 

NOTE 1 

When the master switcher is reset, (e.g. when it is turned on), the reset code is sent to the PC. If this code is sent to the 
switchers, it will reset according to the present power-down settings. 

 
NOTE 2

 – These are bi-directional definitions. That is, if the switcher receives the code, it will perform the instruction; and if 

the instruction is performed (due to a keystroke operation on the front panel), then these codes are sent. For example, if the 
HEX code 
 

01  

85 

81  

83 

was sent from the PC, then the switcher (machine 3) will switch input 5 to output 1. If the user switched input 7 to output 1 
via the front panel keypad, then the switcher will send HEX codes: 
 

41 

87 

81 

83 

to the PC. 
When the PC sends one of the commands in this group to the switcher, then, if the instruction is valid, the switcher replies by 
sending to the PC the same four bytes that it was sent (except for the first byte, where the DESTINATION bit is set high).   

 
NOTE 3

 – SETUP # 0 is the present setting (Status).  

 
NOTE 4

 – The reply to a "REQUEST" instruction is as follows: the same instruction and INPUT codes as were sent are 

returned, and the OUTPUT is assigned the value of the requested parameter. The replies to instruction 5 is per the definitions 
in instruction 1. For example, if the present status of machine number 5 is input 7, then the reply to the HEX code 
 

05 

80 

81 

85 

would be HEX codes 
 

45 

80 

87 

85 

 

NOTE 12 

– Under normal conditions, the machine's present status is saved each time a change is made. The "power-down" 

save (auto-save) may be disabled using this code. Note that whenever the machine is turned on, the auto-save function is set. 
 

NOTE 13

 – This is a request to identify the switcher/s in the system. If the OUTPUT is set as 0, and the INPUT is set as 1, 

the machine will send its name. The reply is the decimal value of the INPUT and OUTPUT. For example, for a VS-121HC, 
the reply to the request to send the audio machine name would be (HEX codes): 
  

7D 

81 

95 

81  (i.e.  1dec for 2nd byte, and  21dec for 3rd byte). 

 
If the OUTPUT is set as 1, then the ASCII coding of the lettering following the machine’s name is sent. For example, for the 
VS-7588YC, the reply to the request to send the first suffix would be (HEX codes): 
 

7D 

C8 

C3 

81  (i.e.  ASCII for “H”;  ASCII for “C”). 

If the request for identification is sent with the INPUT set as 3 or 4, the appropriate machine will send its software version 
number. Again, the reply would be the decimal value of the INPUT and OUTPUT - the INPUT representing the number in 
front of the decimal point, and the OUTPUT representing the number after it. For example, for version 3.5, the reply to the 
request to send the version number would be (HEX codes): 
 

7D 

83 

85 

81  (i.e.  3dec for 2nd byte,  5dec for 3rd byte). 

Содержание VS-121HC

Страница 1: ...Kramer Electronics Ltd USER MANUAL Model VS 121HC 12 x 1 Component Video Switcher Transcoder...

Страница 2: ...ting the ETHERNET Port directly to a PC Crossover Cable 12 7 4 2 Connecting the ETHERNET Port via a Network Hub Straight Through Cable 13 7 4 3 Configuring the Ethernet Port 13 7 5 Operating via the I...

Страница 3: ...121HC in Tandem with the VS 121HCA 16 Figure 10 Splash Screen 19 Figure 11 Atmel Flip Window 20 Figure 12 Device Selection Window 20 Figure 13 Device Selection Window 21 Figure 14 Loading the Hex 21 F...

Страница 4: ...ll modem adapter and rack ears 3 RC IR2 infrared remote control transmitter including the required battery and a separate user manual4 This user manual4 2 Getting Started We recommend that you Unpack...

Страница 5: ...KRAMER SIMPLE CREATIVE TECHNOLOGY Getting Started 2 2 1 Quick Start This quick start chart summarizes the basic setup and operation steps...

Страница 6: ...s The VS 121HC can operate in tandem with the VS 121HCA The VS 121HC can be operated using the front panel buttons or remotely via RS 232 and RS 485 serial commands transmitted by PC a touch screen sy...

Страница 7: ...KRAMER SIMPLE CREATIVE TECHNOLOGY Your VS 121HC Switcher Transcoder 4 Figure 1 VS 121HC 12 x 1 Component Video Switcher Transcoder...

Страница 8: ...ect to the PC or the Remote Controller via a null modem connection 16 RS 485 Terminal Block Port Pins B and A are for RS 485 Pin G may be connected to the shield if required 17 FLASH PROG Button Relea...

Страница 9: ...KRAMER SIMPLE CREATIVE TECHNOLOGY Installing the VS 121HC in a Rack 6 5 Installing the VS 121HC in a Rack This section provides instructions for rack mounting the unit...

Страница 10: ...Y Pb Cb Pr Cr COMPONENT INPUT 12 RCA connectors 2 Connect the output to an acceptor 1 or 2 output devices can be connected1 COMPONENT OUTPUT B Y Pb Cb Pr Cr RCA connectors to a display3 3 Connect the...

Страница 11: ...nel buttons see section 7 1 The RS 232 port see section 7 2 The RS 485 port see section 7 3 An Ethernet network see section 7 4 The RC IR2 remote control transmitter1 7 5 see section This section also...

Страница 12: ...e VS 121HC via an RS 232 connection using for example a PC Note that a null modem adapter connection is not required To connect to the VS 121HC via RS 232 connect the RS 232 9 pin D sub rear panel por...

Страница 13: ...low control jumpering described in Method A above only requires pins 2 3 and 5 to be connected you are free to decide whether to connect only these 3 pins or all 9 pins Figure 4 Straight Cable RS 232...

Страница 14: ...orrect operation the RS 485 line must be terminated at both ends The master unit may be located at any part of the line but when it is at the end of the line the termination switch must be set ON To s...

Страница 15: ...port of the VS 121HC to the Ethernet port on your PC via a crossover cable with RJ 45 connectors This type of connection is recommended for identification of the factory default IP Address of the VS 1...

Страница 16: ...Through Cable You can connect the Ethernet port of the VS 121HC to the Ethernet port on a network hub or network router via a straight through cable with RJ 45 connectors 7 4 3 Configuring the Ethern...

Страница 17: ...REMOTE IR 3 5mm connector can be used Connect the external IR receiver to the REMOTE IR 3 5mm connector To operate your device using the infra red remote controller see the User Manual packed with the...

Страница 18: ...ected via RS 232 to be machine number 1 The other VS 121HC units must each be set to a unique machine number between 2 and 16 Table 4 Machine Number DIP switch Settings Machine Number DIP switch Machi...

Страница 19: ...RS 232 or the Ethernet ports of the VS 121HC To set the VS 121HC to operate in tandem with the VS 121HCA 1 Set the machine number on both units to 1 DIP switches 1 2 3 and 4 are set OFF 2 Connect the...

Страница 20: ...5dB 1Vpp all channels CONTROLS 12 selector buttons lock button RS 232 RS 485 Ethernet IR POWER SOURCE 100 240V AC 50 60Hz 115V AC U S A 7VA DIMENSIONS 19 inch W 7 inch D 1U H rack mountable WEIGHT 2 6...

Страница 21: ...ct a PC to the RS 232 port see section 9 1 2 Install the latest firmware see section 9 1 3 9 1 1 Downloading from the Internet To download the latest file1 1 Go to our Web site at from the Internet ww...

Страница 22: ...g the Device Firmware To install the firmware perform the following steps 1 Double click the desktop icon Shortcut to FLIP EXE The Splash screen appears1 Figure 10 Splash Screen 2 After a few seconds...

Страница 23: ...w by pressing the keyboard shortcut key F2 or choosing the Select command from the Device menu or pressing the integrated circuit icon in the upper right corner of the window The Device Selection wind...

Страница 24: ...Upgrading the VS 121HC Firmware 21 AT89C51RD2 T89C51RD2 Figure 13 Device Selection Window 5 Click OK 6 From the File menu select Load Hex Figure 14 Loading the Hex...

Страница 25: ...cation RS232 command from the Settings menu or press the keys Alt SCR The RS232 window appears 9 Change the COM port settings according to the configuration of your computer and select the 9600 baud r...

Страница 26: ...VS 121HC 14 If required disconnect the null modem adapter from the VS 121HC 15 Press the FLASH PROG button on the front panel of the VS 121HC outward to its original position see Figure 1 16 Power ON...

Страница 27: ...2 2 Connecting the PC to the RS 232 Port To connect a PC to the RS 232 port of the VS 121HC 1 Power the VS 121HC OFF 2 Connect a serial cable from the VS 121HC RS 232 9 pin D sub rear panel port to a...

Страница 28: ...tward to its original position see Figure 1 8 Power ON the VS 121HC 10 Hex Table Table 7 lists the Hex values which the protocol in section 11 describes in more detail for the VS 121HC Switcher and Tr...

Страница 29: ...low INSTRUCTION NO is the value to be set for N5 N0 2nd BYTE Bit 7 Defined as 1 I6 I0 INPUT When switching ie instruction codes 1 and 2 the INPUT 7 bits is set as the input number which is to be switc...

Страница 30: ...the first byte where the DESTINATION bit is set high NOTE 3 SETUP 0 is the present setting Status NOTE 4 The reply to a REQUEST instruction is as follows the same instruction and INPUT codes as were...

Страница 31: ...at here the OUTPUT is assigned with the value 0 if the panel is unlocked or 1 if it is locked NOTE 26 After this instruction is sent with OUTPUT defined OFF the unit will not send reply to the protoco...

Страница 32: ...heractsofnature ii Product modification orfailureto followinstructions supplied with theproduct iii Repairorattemptedrepairby anyonenot authorized byKramer iv Anyshipment oftheproduct claims must bepr...

Страница 33: ...or the latest information on our products and a list of Kramer distributors visit our Web site www kramerelectronics com where updates to this user manual may be found We welcome your questions commen...

Отзывы: