KRAMER: SIMPLE CREATIVE TECHNOLOGY
Kramer Protocol
44
Machine info commands
Command
Syntax
Response
* Time settings commands require admin authoriza ion
Read in\outs count
INFO-IO?
INFO-IO: IN
INPUTS_COUNT
,
OUT
OUTPUTS_COUNT
Read max presets
count
INFO-PRST?
INFO-PRST: VID
PRESET_VIDEO_COUNT
,
AUD
PRESET_AUDIO_COUNT
Reset configuration to
factory default
FACTORY
FACTORY
RESULT
Mute Audio
MUTE MUTE MODE
MUTE MUTE MODE RESULT
Identification commands
Command
Syntax
Response
Protocol Handshaking
#
CR
~OK
CRLF
Read device model
MODEL?
MODEL
MACHINE_MODEL
Read device serial number
SN?
SN
SERIAL_NUMBER
Read device firmware version
VERSION?
VERSION
MAJOR .MINOR .BUILD .REVISION
Set machine name
NAME
MACHINE_NAME
NAME
MACHINE_NAME
RESULT
Read machine name
NAME?
NAME
MACHINE_NAME
Reset machine name to factory
default*
NAME-RST
NAME-RST
MACHINE_FACTORY_NAME RESULT
*Note: machine name not equal to model name. This name relevance for site viewer identification of specific machine or for
network using (with DNS feature on).
MACHINE_NAME
= Up to 14 Alfa-Numeric chars.
*
Machine factory name =
Model name + last 4 digits from serial number.
Set machine id number
MACH-NUM
MACHINE_NUMBER
MACH-NUM OLD_MACHINE_NUMBER
,NEW_MACHINE_NUMBER RESULT
* Response will send after machine number has been changed. So the replay with header will be:
NEW_MACHINE_NUMBER
@
MACH-NUM OLD_MACHINE_NUMBER
NEW_MACHINE_NUMBER
OK
Network settings commands
Set IP Address
NET-IP
IP_ADDRESS
NTIP
NET-IP
IP_ADDRESS RESULT
Read IP Address
NET-IP?
NTIP
?
NET-IP
IP_ADDRESS
Read MAC Address
NET-MAC?
NTMC
NET-MAC
MAC_ADDRESS
Set subnet mask
NET-MASK
SUBNET_MASK
NTMSK
NET-MASK
SUBNET_MASK RESULT
Read subnet mask
NET-MASK?
NTMSK?
NET-MASK
SUBNET_MASK