6.6 Setting the Dipswitches
By default, all dipswitches are set to OFF. Figure 11 illustrates the
VP-8x8A
dipswitches:
OFF
ON
1 2 3 4
1 2 3 4 5 6 7 8
Figure 11: VP-8x8A Dipswitches
Table 7: Dipswitch Settings
DIPS
Function
Description
1, 2, 3
DELAY
Determines switching delay time
4
Reserved
Set to OFF
1, 2, 3, 4
Mach. #
Determines the number of the machine in the
sequence
5, 6, 7
Reserved
Set to OFF
8
S
E
TU
P
RS-485 TERM ON for RS-485 Line Termination with 120 ;
OFF for no RS-485 Line Termination
6.6.1
Setting the Delay
You can achieve clean transitions when switching between non-genlocked
sources by setting the delay time—ranging from 0sec to 3.5sec
1
—via the
DELAY dipswitches, as Table 8 defines. The
VP-8x8A
unit is shipped (its
factory default state) with no delay, that is, the DELAY dipswitches are set to
OFF for a 0sec delay.
Table 8: DELAY Dipswitch Settings
sec
DIP 1
DIP 2
DIP 3
0
OFF
OFF
OFF
0.5
OFF
OFF
ON
1.0
OFF
ON
OFF
1.5
OFF
ON
ON
2.0
ON
OFF
OFF
2.5
ON
OFF
ON
3.0
ON
ON
OFF
3.5
ON
ON
ON
1 In increments of 0.5sec