VP-480 - Operating the VP-480 CV to 3G HD-SDI Scaler
11
6.2.3
Color Sub-menu
Options
Function
Value Range
Factory Default
RED
Sets the output red value
0-100
48
GREEN
Sets the output green value
0-100
48
BLUE
Sets the output blue value
0-100
52
EXIT
Returns to the main menu
6.2.4
Audio Sub-menu
Options
Function
Value Range
Factory
Default
DELAY
Sets the audio delay
OFF, 40ms, 110ms, 150ms
OFF
SOUND
Turns the sound on or off
ON, MUTE
ON
EXIT
Returns to the main menu
6.2.5
OSD Sub-menu
Main Menu
Submenu
Function
Value
Range
Factory
Default
H-POSITION
Sets the right/left position of the OSD on the
screen
0-100
10
V-POSITION
Sets the up/down position of the OSD on the
screen
0-100
90
TIMER
Sets the length of time (in seconds) that the
OSD remains visible on the screen
0-100
10
BACKGROUND
Sets the darkness of the OSD background
0-100
63
DISPLAY
Displays the input signal state and current
output resolution on the output
INFO, ON,
OFF
INFO
EXIT
Returns to the main menu