background image

KRAMER:  SIMPLE CREATIVE TECHNOLOGY

 

Kramer Protocol 2000 

 

42 

INSTRUCTION 

DEFINITION FOR SPECIFIC INSTRUCTION 

DESCRIPTION 

INPUT 

OUTPUT 

NOTE 

Set equal to audio input  

(0 = disconnect) 

Set equal to audio output  

(0 = to all the outputs) 

60   LOAD AUDIO DATA 

(127 = load SETUP #) 

or SETUP # 

21, 22 

61  IDENTIFY MACHINE  

1 - video machine name 

2 - audio machine name 

3 - video software version 

4 - audio software version 

5 - RS422 controller name 

6 - RS422 controller version 

7 - remote control name 

8 - remote software version 

9 - Protocol 2000 revision 

0 - Request first 4 digits 

1 - Request first suffix 

2 - Request second suffix 

3 - Request third suffix 

10 - Request first prefix 

11 - Request second prefix 

12 - Request third prefix 

13 

62  DEFINE MACHINE  

1 - number of inputs 

2 - number of outputs 

3 - number of setups 

1 - for video 

2 - for audio 

3 - for SDI 

4 - for remote panel 

5 - for RS-422 controller 

14 

63  EXTENDED DATA 

7 MSBs for INPUT data 

7 MSBs for OUTPUT data 

19 

 

NOTES on the above table: 

 

NOTE 1

 - When the master switcher is reset, (e.g. when it is turned on), the reset code is sent to the PC. If this code is sent to 

the switchers, it will reset according to the present power-down settings. 

 

NOTE 2

 - These are bi-directional definitions. That is, if the switcher receives the code, it will perform the instruction; and if 

the instruction is performed (due to a keystroke operation on the front panel), then these codes are sent. For example, if the 

HEX code 

01  

85 

88  

83 

was sent from the PC, then the switcher (machine 3) will switch input 5 to output 8. If the user switched input 1 to output 7 

via the front panel keypad, then the switcher will send HEX codes: 

41 

81 

87 

83 

to the PC. 

When the PC sends one of the commands in this group to the switcher, then, if the instruction is valid, the switcher replies by 

sending to the PC the same four bytes that it was sent (except for the first byte, where the DESTINATION bit is set high).   

 

NOTE 3

 - SETUP # 0 is the present setting. SETUP # 1 and higher are the settings saved in the switcher's memory, (i.e. those 

used for Store and Recall). 

 

NOTE 4

 - The reply to a "REQUEST"  instruction is as follows: the same instruction and  INPUT codes as were sent are 

returned, and the OUTPUT is assigned the value of the requested parameter. The replies to instructions 10 and 11 are as per 

the  definitions  in  instructions  7  and  8  respectively.  For  example,  if  the  present  status  of  machine  number  5  is  breakaway 

setting, then the reply to the HEX code 

0B 

80 

80 

85 

would be HEX codes 

4B 

80 

81 

85 

 

NOTE 5

 – For the OUTPUT byte set as 6, the VIS source is the input selected using the OUTPUT byte. Similarly, for the 

OUTPUT byte set as 7, the VIS source is the output selected using the OUTPUT byte. Note also, that on some machines the 

sync source is not software selectable, but is selected using switches, jumpers, etc!  

 

NOTE  6

  –  If  INPUT  is  set  to  127  for  these  instructions,  then,  if  the  function  is  defined  on  this  machine,  it  replies  with 

OUTPUT=1. If the function is not defined, then the machine replies with OUTPUT=0, or with an error (invalid instruction 

code).  

 

If the INPUT is set to 126 for these instructions, then, if possible, the machine will return the current setting of this function, 

even for the case that the function is not defined. For example, for a video switcher which always switches during the VIS of 

input # 1, (and its VIS setting cannot be programmed otherwise), the reply to the HEX code 

0A 

FE 

80 

81 (i.e. request VIS setting, with INPUT set as 126dec)  

would be HEX codes 

4A 

FE 

81 

81 (i.e. VIS setting = 1, which is defined as VIS from input # 1). 

 

NOTE 7

 – Setting OUTPUT to 0 will return the VIS source setting as defined in instruction # 7. Setting to 1 will return the 

input # or output # of the sync source (for the case where the VIS source is set as 6 or as 7 in instruction # 7). Setting to 2 

returns the vertical sync frequency (0 for no input sync, 50 for PAL, 60 for NTSC, 127 for error).  

 

Содержание VP-1201

Страница 1: ...Kramer Electronics Ltd USER MANUAL Model VP 1201 12x1 XGA Switcher Scanner...

Страница 2: ...everal VP 1201 Machines 24 5 5 1 Connecting Several VP 1201 Units Individual Control Configuration 24 5 5 2 Connecting Several VP 1201 Units Input Expansion Configuration 26 5 6 Control Configuration...

Страница 3: ...Port Settings Window 17 Figure 16 Dedicated Connection Window 17 Figure 17 Flush Mode Input Buffer Window 17 Figure 18 Com Port Redirector Welcome Screen 18 Figure 19 Setup Complete Dialog Box 19 Fig...

Страница 4: ...ble 6 Web Manager Window Buttons 14 Table 7 Port Settings Description 22 Table 8 Dipswitch Settings 28 Table 9 MACH ADDR Dipswitch Settings 29 Table 10 MACH Dipswitch Settings 29 Table 11 DWELL TIME D...

Страница 5: ...figuration Manager XPort software and Com Port Redirector Windows based Kramer control software This user manual2 2 Getting Started We recommend that you Unpack the equipment carefully and save the or...

Страница 6: ...ontrol Transmitter1 The VP 1201 is dependable rugged and fits into one vertical space 1U of a standard 19 rack To achieve the best performance Connect only good quality connection cables thus avoiding...

Страница 7: ...Your VP 1201 12x1 XGA Switcher Scanner 3 Figure 1 VP 1201 12x1 XGA Switcher Scanner...

Страница 8: ...r Features Feature Function 4 HD15F Input Connectors Connect to the video sources IN1 through IN12 5 HD15F BUS Connector Bus connector for cascading VP 1201 units 6 HD15F BUS LOOP Connector Loop for b...

Страница 9: ...section 5 3 ETHERNET see sections 5 4 and 5 6 Connect several VP 1201 machines see section 5 5 Set the dipswitches see section 5 7 Reset the unit see section 5 8 5 1 Connecting a Single Unit or Multip...

Страница 10: ...KRAMER SIMPLE CREATIVE TECHNOLOGY Connecting a VP 1201 12x1 XGA Switcher Scanner 6 Computer Graphic Source 1 Display Computer Graphic Source 12 RS 232 Figure 3 Connecting the VP 1201...

Страница 11: ...re flat cable2 to the RS 232 DB9 port on your PC To connect a PC to the VP 1201 unit1 without using a Null modem adapter Connect the RS 232 DB9 port on your PC to the RS 232 DB9 rear panel port on the...

Страница 12: ...1201 unit If shielded twisted pair cable is used the shield may be connected to the G Ground PIN on one of the units for example on the RC 3000 2 Set the MACH dipswitches on the VP 1201 unit to Machi...

Страница 13: ...er Cable Connect the ETHERNET port of the VP 1201 to the LAN port on your PC via a crossover cable with RJ 45 connectors as Table 4 defines Table 4 Crossover Cable RJ 45 PINOUT Side 1 Side 2 PIN Wire...

Страница 14: ...10 5 Select the Internet Protocol TCP IP and click the Properties Button see Figure 6 Figure 6 Local Area Connection Properties Window 6 Select Use the following IP Address and fill in the details as...

Страница 15: ...t is important to consider the following points before logging into and configuring the ETHERNET Port The VP 1201 IP address must be configured before a network connection is available Only one person...

Страница 16: ...ned at the factory The Hardware Address is an individual permanent address assigned to a particular device on the network The Hardware Address can be found on the product label inside the unit Note Cl...

Страница 17: ...eive Reply messages make sure the unit is properly attached to the network and that the IP address assigned is valid for the particular network segment you are working with If you are not sure check w...

Страница 18: ...rst click one of the devices listed in the window and then click the Web icon The Web Manager window now displays in your browser Figure 11 ETHERNET Port Web Manager Table 6 describes the Web Manager...

Страница 19: ...finished click the Update Settings button to save your settings 5 4 4 1 Unit Configuration Button Click the Unit Configuration button to display the following dialog box Figure 12 This page contains t...

Страница 20: ...fields Hold the cursor over one of the fields to display Help messages Figure 14 Server Properties in the Unit Configuration Window Changing the IP address will require you to enter the new IP addres...

Страница 21: ...rding to Figure 151 Figure 15 Serial Port Settings Window Make sure that the Local Port in the Dedicated Connection window is set according to Figure 16 Figure 16 Dedicated Connection Window Make sure...

Страница 22: ...t on the server 5 4 5 1 Installing the Com Port Redirector To install the Com Port Redirector do the following 1 Perform the appropriate step to start the installation If the Com Port Redirector is on...

Страница 23: ...onfiguration The Com Port Redirector Configuration window appears see Figure 20 Figure 20 Com Port Redirector Configuration Window 6 Click the Com Setup button A Port Setup dialog box appears Figure 2...

Страница 24: ...n finished click OK Note After you use the Port Setup dialog box to add or remove Com ports restart your computer 5 4 5 2 Configuring the Com Port Redirector Com Port Redirector is a software utility...

Страница 25: ...e section 5 4 1 To configure the Com Port Director 1 Click the Start button in the Windows Taskbar point to Programs point to Lantronix Redirector and click Configuration The Com Port Redirector Confi...

Страница 26: ...giving up on this attempt If Timeout Reconnect is enabled each connection attempt lasts this long If Timeout Reconnect is disabled the connection attempt fails after this interval and no more attempts...

Страница 27: ...window opens a pop up window displays Attempting to connect to service If this message is replaced by Successfully redirected to service the connection from the Com Port Redirector to the device serv...

Страница 28: ...1 units see Figure 25 do the following 1 Connect the video sources and acceptors as section 5 describes 2 Turn ON the power not illustrated 3 Connect the RS 232 port on the first VP 1201 unit to the P...

Страница 29: ...Switcher Scanner 25 1 1 1 ON ON ON OFF OFF OFF 2 2 2 3 3 3 4 4 4 5 5 5 6 6 6 7 7 7 8 8 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Machine 16 Machine 2 Figure 25 Connecting VP 1201 Machines Ind...

Страница 30: ...irst VP 1201 unit Attach the Cable s second 15 pin HD connector to the 15 pin HD BUS Loop on the second VP 1201 unit Continue attaching the 15 pin HD connectors on each VP 1201 unit up to and includin...

Страница 31: ...achine 1 Machine Address 3 1 1 ON ON OFF OFF 2 2 3 3 4 4 5 5 6 6 7 7 8 8 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 1 ON OFF 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Figure 26 Connecting VP 1201 Machines Input Expansion Co...

Страница 32: ...Line Termination 1 2 3 4 DWELL TIME Determines scanning delay time the number of seconds each input is connected to the output in the Scanner mode 5 SCAN ON for Scanner mode OFF for switcher mode 6 V...

Страница 33: ...n the Input Expansion configuration set an identical MACH on all units When connecting other machines in the Individual Control configuration set the MACH to subsequent numbers For example 1 for the f...

Страница 34: ...time see section 5 7 4 3 Set the other dipswitches according to the machine configuration 5 7 4 DWELL TIME Dipswitches Setup The DWELL TIME dipswitches setup determines the number of seconds1 each in...

Страница 35: ...VP 1201 The VP 1201 can operate in two different modes Switcher mode inputs are selected manually Move from one signal to another by pressing the appropriate input button Scanner mode inputs are autom...

Страница 36: ...he front panel we can see that The blue LEDs in buttons 1 5 and 10 are illuminated indicating that these 3 sources are connected and active The red LED in button 2 is illuminated indicating that Input...

Страница 37: ...zip to a folder for example C Program Files Kramer Flash 3 Create a shortcut on your desktop to the file FLIP EXE 7 2 Connecting the PC to the RS 232 Port Before installing the latest Kramer firmware...

Страница 38: ...ash screen is replaced by the Atmel Flip window Figure 31 Atmel Flip Window 3 Press the keyboard shortcut key F2 or select the Select command from the Device menu or press the integrated circuit icon...

Страница 39: ...k the button next to the name of the device and select from the list AT89C51RD2 AT89C51RD2 T89C51RD2 Figure 33 Selecting Device from Selection Window 5 Click OK and select Load Hex from the File menu...

Страница 40: ...from the Settings menu or press the keys Alt SCR The RS232 window appears Change the COM port according to the configuration of your computer and select the 9600 baud rate Figure 35 RS 232 Window 8 Cl...

Страница 41: ...ssage Memory Verify Pass appears2 VP1201 hex A Figure 37 Atmel Flip Window Operation Completed 10 Close the Atmel Flip window 11 Disconnect the power on the VP 1201 12 If required disconnect the RS 23...

Страница 42: ...nch D 1U H rack mountable WEIGHT 2 7 kg 6 lbs approx ACCESSORIES Power cord Null modem adapter Windows based control software Windows based Configuration Manager XPort software and Com Port Redirector...

Страница 43: ...NO is the value to be set for N5 N0 2nd BYTE Bit 7 Defined as 1 I6 I0 INPUT When switching ie instruction codes 1 and 2 the INPUT 7 bits is set as the input number which is to be switched Similarly i...

Страница 44: ...PUT byte 8 User defined sync 64 Set for delayed switch 65 Execute delayed switch 66 Cancel delayed switch setting 2 5 17 0 0 audio follow video 1 audio breakaway 2 8 BREAKAWAY SETTING 1 0 FOLLOW mode...

Страница 45: ...rease output 2 increase left output 3 decrease left output 4 increase right output 5 decrease right output 6 increase input 7 decrease input 8 increase left input 9 decrease left input 10 increase rig...

Страница 46: ...first byte where the DESTINATION bit is set high NOTE 3 SETUP 0 is the present setting SETUP 1 and higher are the settings saved in the switcher s memory i e those used for Store and Recall NOTE 4 Th...

Страница 47: ...ould be HEX codes 7D 83 85 81 i e 128dec 3dec for 2nd byte 128dec 5dec for 3rd byte If the OUTPUT is set as 1 then the ASCII coding of the lettering following the machine s name is sent For example fo...

Страница 48: ...of the unit e g the EEPROM for saving SETUPS The EEPROM address is sent using the INPUT byte and the data to be stored is sent using the OUTPUT byte To use this instruction it is necessary to underst...

Страница 49: ...riginal dated invoice or a copy must be presented as proof of warranty coverage and should be included in any shipment of the product Please also include in any mailing a contact name company address...

Страница 50: ...ail info kramerel com P N 2900 000017 REV 1 For the latest information on our products and a list of Kramer distributors visit our Web site www kramerelectronics com where updates to this user manual...

Отзывы: