![Kramer VP-108 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/kramer/vp-108/vp-108_user-manual_2000696013.webp)
Connecting the VP-108 1:8 XGA / Balanced Stereo Audio DA
9
6.2.2
Setting the MACHINE #
The MACHINE # determines the position of a
VP-108
unit, specifying which
VP-108
unit is being controlled when several
VP-108
units connect to a PC
or serial controller. Set the MACHINE # on a
VP-108
unit via DIPS 1, 2 and
3, according to Table 4.
When using a stand-alone
VP-108
unit, set the MACHINE # to 1. When
connecting more than one
VP-108
unit, set the first machine (the Master) that
is closest to the PC, as
MACHINE #
1
1
.
Table 4: Machine # Dipswitch Settings
DIPSWITCH
MACHINE #
1
2
3
1
Master
OFF OFF OFF
2
ON OFF OFF
3
OFF ON OFF
4
ON ON OFF
5
OFF OFF ON
6
ON OFF ON
7
OFF ON ON
8
ON ON ON
6.3 Connecting the REMOTE Connector
Connecting the REMOTE terminal block connector pins to a contact closure
switch lets you to disable (and then enable again) output(s) by remote
control
2
. To do so, touch (momentarily) the appropriate REMOTE terminal
block connector pin to the Ground PIN, as Figure 9 illustrates.
For example to disable outputs 1, 2 and 8, touch (momentarily) PIN 1 to the
Ground PIN, and then touch (momentarily) PIN 2 to the Ground PIN, and then
touch (momentarily) PIN 8 to the Ground PIN.
Do not touch (momentarily) more than one PIN to the Ground PIN
simultaneously.
1 Set the dipswitches to OFF
2 An output may also be disabled via RS-232 or RS-485