background image

Kramer Electronics Ltd. 

 

VM-10H2 

– Default EDID 

 

Default EDID 

Monitor 

  Model name............... VM-10H2 
  Manufacturer............. KMR 
  Plug and Play ID......... KMR1200 
  Serial number............ n/a 
  Manufacture date......... 2016, ISO week 14 
  Filter driver............ None 

  

-------------------------  

  EDID revision............ 1.3 
  Input signal type........ Digital 
  Color bit depth.......... Undefined 
  Display type............. Monochrome/grayscale 
  Screen size.............. 520 x 320 mm (24.0 in) 
  Power management......... Standby, Suspend, Active off/sleep 
  Extension blocs.......... 1 (CEA-EXT) 

  

-------------------------  

  DDC/CI................... Not supported 

 

Color characteristics 

  Default color space...... Non-sRGB 
  Display gamma............ 2.20 
  Red chromaticity......... Rx 0.674 - Ry 0.319 
  Green chromaticity....... Gx 0.188 - Gy 0.706 
  Blue chromaticity........ Bx 0.148 - By 0.064 
  White point (default).... Wx 0.313 - Wy 0.329 
  Additional descriptors... None 

 

Timing characteristics 

  Horizontal scan range.... 30-83kHz 
  Vertical scan range...... 56-76Hz 
  Video bandwidth.......... 170MHz 
  CVT standard............. Not supported 
  GTF standard............. Not supported 
  Additional descriptors... Established timings 
  Preferred timing......... Yes 
  Native/preferred timing.. 1920x1080p at 60Hz  

    Modeline............... "1920x1080" 148.500 1920 2008 2052 2200 1080 1084 1089 1125 +hsync +vsync 

 

Standard timings supported 

    

 

640

 

x  480p at  60Hz - IBM VGA 

    

 

640

 

x  480p at  72Hz - VESA 

    

 

640

 

x  480p at  75Hz - VESA 

    

 

800

 

x  600p at  60Hz - VESA 

    

 

800

 

x  600p at  72Hz - VESA 

    

 

800

 

x  600p at  75Hz - VESA 

   

 

1024

 

x  768p at  60Hz - VESA 

   

 

1024

 

x  768p at  70Hz - VESA 

   

 

1024

 

x  768p at  75Hz - VESA 

   

 

1280

 

x 1024p at  75Hz - VESA 

   

 

1600

 

x  900p at  60Hz - VESA STD 

   

 

1280

 

x  800p at  60Hz - VESA STD 

   

 

1600

 

x 1200p at  60Hz - VESA STD 

   

 

1024

 

x  768p at  85Hz - VESA STD 

    

 

800

 

x  600p at  85Hz - VESA STD 

    

 

640

 

x  480p at  85Hz - VESA STD 

   

 

1152

 

x  864p at  75Hz - VESA STD 

   

 

1280

 

x  960p at  60Hz - VESA STD 

    

 

848

 

x  480p at  60Hz - VESA 

   

 

1280

 

x  768p at  60Hz - VESA 

   

 

1280

 

x 1024p at  60Hz - VESA 

   

 

1360

 

x  768p at  60Hz - VESA 

   

 

1440

 

x  900p at  60Hz - VESA 

   

 

1400

 

x 1050p at  60Hz - VESA 

   

 

1650

 

x 1050p at  60Hz - VESA 

 

EIA/CEA-861 Information 

  Revision number.......... 3 
  IT underscan............. Supported 
  Basic audio.............. Supported 
  YCbCr 4:4:4.............. Not supported 
  YCbCr 4:2:2.............. Not supported 
  Native formats........... 1 
  Detailed timing #1....... 720x480i at 30Hz  

    Modeline............... "720x480" 8.490 720 808 857 981 480 488 498 570 inthsync +vsync 

  Detailed timing #2....... 852x480p at 60Hz (16:9) 
   

  Modeline............... "852x480" 49.450 852 1380 1429 1572 480 484 489 525 +hsync +vsync 

Содержание VM-10H2

Страница 1: ...P N 2900 300619 Rev 1 www kramerAV com USER MANUAL MODEL VM 10H2 4K HDMI 2 0 1 10 DA...

Страница 2: ...0H2 4K HDMI 2 0 1 10 DA 4 Mounting VM 10H2 5 Connecting the VM 10H2 6 Connecting to VM 10H2 via RS 232 6 Operating the VM 10H2 7 Setting the DIP Switches 7 Acquiring and Setting the Current EDID 8 Def...

Страница 3: ...tight bundles or roll the slack into tight coils Avoid interference from neighboring electrical appliances that may adversely influence signal quality Position your Kramer VM 10H2 away from moisture...

Страница 4: ...ibuted to ten identical output signals with signals rebuilt using Kramer Equalization re Klocking Technology to gain longer distances HDMI Signal Transmission HDR HDMI 2 0 and HDCP 2 2 compliant signa...

Страница 5: ...indicate a firmware update 2 Power VM 10H2 OFF and ON for the new DIP switch settings to activate Optionally connect RS 232 to PC to use Hercules to track firmware upgrade progress 3 Plug a USB cable...

Страница 6: ...LED Lights green when an active input signal is detected OUT LEDs 1 to 10 Lights green when an active output acceptor is detected flashes when HDCP is not supported by the acceptor PROGRAM USB Connec...

Страница 7: ...10H2 in the rack before connecting any cables or power Warning Ensure that the environment e g maximum ambient temperature air flow is compatible for the device Avoid uneven mechanical loading Appropr...

Страница 8: ...3 Connect the ten OUT connectors to up to ten HDMI acceptors for example 4K displays Not all outputs must be connected 4 Connect the power cord to the mains electricity 5 Turn ON the POWER 6 Acquire t...

Страница 9: ...ent to improve picture quality Up Use stored EDID default Down Use stored EDID and force source RGB support EDID lock Up EDID lock on Down EDID lock off default Auto EDID Up Use stored EDID default Do...

Страница 10: ...ess selects the 1st output port and the sequence begins again 3 When the desired EDID source is reached press the EDID READ button VM 10H2 reads the EDID for a few seconds and syncs the displays Upon...

Страница 11: ...Modeline 1920x1080 148 500 1920 2008 2052 2200 1080 1084 1089 1125 hsync vsync Standard timings supported 640 x 480p at 60Hz IBM VGA 640 x 480p at 72Hz VESA 640 x 480p at 75Hz VESA 800 x 600p at 60Hz...

Страница 12: ...6 20 24 bit depths at 32 44 48 kHz CE speaker allocation data Channel configuration 2 0 Front left right Yes Front LFE No Front center No Rear left right No Rear center No Front left right center No R...

Страница 13: ...er LED Power Consumption 100 240V AC 50 60Hz 15VA Source 100 240V AC 50 60Hz 55VA Environmental Conditions Operating Temperature 0 to 40 C 32 to 104 F Storage Temperature 40 to 70 C 40 to 158 F Humidi...

Страница 14: ...ilder Kramer software K Config Kramer configuration software All the examples provided in this section are based on using the K Config software You can enter commands directly using terminal communica...

Страница 15: ...arated by a pipe character Message starting character For host command query For device response Device address K NET Device ID followed by optional K NET only Query sign follows some commands to defi...

Страница 16: ...rmat Start Address optional Body Delimiter Device_id Message CR Simple Command Command string with only one command without addressing Start Body Delimiter Command Parameter_1 Parameter_2 CR Command S...

Страница 17: ...Get device model System mandatory End User PROT VER Get device protocol version System mandatory End User RESET Reset device System mandatory Administrator SN Get device serial number System mandatory...

Страница 18: ...ss where hh hours mm minutes ss seconds Response Triggers Notes K Config Example BUILD DATE 0x0D FACTORY Functions Permission Transparency Set FACTORY End User Public Get Description Syntax Set Reset...

Страница 19: ...sageCR LF Parameters Response Triggers Notes K Config Example 1 Get a list of all VM 10H2 commands HELP 0x0D 2 Get help for the ETH PORT command HELP ETH PORT 0x0D MODEL Functions Permission Transpare...

Страница 20: ...al digit Response Triggers Notes K Config Example PROT VER 0x0D RESET Functions Permission Transparency Set RESET Administrator Public Get Description Syntax Set Reset device RESETCR Get Response nn R...

Страница 21: ...l_number 14 decimal digits factory assigned Response Triggers Notes K Config Example SN 0x0D VERSION Functions Permission Transparency Set Get VERSION End User Public Description Syntax Set Get Get fi...

Страница 22: ...us System End User AV SW TIMEOUT Functions Permission Transparency Set AV SW TIMEOUT End User Public Get AV SW TIMEOUT End User Public Description Syntax Set Set auto switching timeout AV SW TIMEOUTSP...

Страница 23: ...port from which the Get was received Response is sent after every change in output HPD status ON to OFF Response is sent after every change in output HPD status OFF to ON and ALL parameters new EDID...

Страница 24: ...ent to all com ports after execution if HDCP STAT was set by any other external control device button press device menu and similar or HDCP mode changed Notes On output sink status On input signal sta...

Страница 25: ...t_type EDID destination type usually input 0 Input 1 Output 2 Default EDID 3 Custom EDID dest_bitmap bitmap representing destination IDs Format XXXX X where X is hex digit The binary form of every hex...

Страница 26: ...OKCR LF Get nn GEDIDSPstage stage_id sizeCR LF Parameters stage input output 0 Input 1 Output 2 Default EDID 3 Custom EDID stage_id number of chosen stage 1 max number of inputs outputs size EDID data...

Страница 27: ...as is without trying to adjust 1 Device tries to adjust the EDID EDID_DATA data in protocol packets The packet protocol is designed to transfer large amounts of data such as files IR commands EDID dat...

Страница 28: ...e insured during shipment with the insurance and shipping charges prepaid by you If this product is returned uninsured you assume all risks of loss or damage during shipment Kramer Electronics will no...

Страница 29: ...RNING Disconnect the unit from the power supply before opening andservicing For the latest information on our products and a list of Kramer distributors visit our Web site where updates to this user m...

Отзывы: