12
VA-8xl - Controlling the VA-8xl
Method B
(
Figure 8
)—Connect the RS-232 9-pin D-sub port on the unit via a
straight (flat) cable to the null-modem adapter, and connect the null-modem
adapter to the RS-232 9-pin D-sub port on the PC. The straight cable usually
contains all nine wires for a full connection of the D-sub connector. Because the
null-modem adapter (which already includes the flow control jumpering described
in Method A above) only requires pins 2, 3 and 5 to be connected, you are free to
decide whether to connect only these 3 pins or all 9 pins.
Figure 8: Straight Cable RS-232 Connection with a Null Modem Adapter
6.2.1
DIP-Switch Settings
Configure the
VA-8xl
by setting the DIP-switches as defined in
Figure 9
:
Figure 9: Rear Panel DIP-switches (Factory Default)
DIP #
Function:
1-4
Set the MACHINE # (see
Section 6.2.2
)
5
Not used
6
RS-485 termination for first and last machine = ON (RS-485 line terminates with
110
Ω
); for others = OFF (RS-485 line is open)
7/8
Used for the firmware upgrade procedure (see
Section 7
)
6.2.2
Setting the MACHINE #
To control a unit via RS-232 or RS-485, each unit has to be identified via its
unique MACHINE #. Set the MACHINE # on a
VA-8xl
unit according to the
following table. A valid MACHINE # is from 1 to 15.
1
2
6
3
7
4
8
5
9
to PC
Null-Modem
Adapter
Содержание VA-8XL
Страница 2: ......
Страница 10: ...VA 8xl Connecting the VA 8xl 7 Figure 6 Connecting the VA 8xl 8 Channel Balanced Stereo Audio Amplifier...
Страница 20: ...VA 8xl Controlling the VA 8xl 17 Figure 12 An RS 485 Control Interface Setup...
Страница 32: ...VA 8xl Kramer Protocol 2000 29...
Страница 33: ...P N 2900 300151 Rev 1...