4
Defining the TP
‑
580TD DVI Line
Transmitter
Figure 1:
TP
‑
580TD
DVI Line Transmitter
#
Feature
Function
IN
LED
Lights green when an active DVI source device input signal is detected.
OUT LED
Lights green when an active, far-end sink (acceptor) DVI output signal is detected
via the HDBaseT link (a DVI signal is detected from a sink device connected to
the HDBaseT receiver that is connected to this output).
LINK
LED
Lights green when an HDBT link is established with the HDBaseT receiver.
ON
LED
Lights green when the device receives power.
HDBT OUT RJ-45
Connector
Connect to the HDBT IN connector on a receiver (for example,
TP
‑
580RD
).
DVI IN Connector Connect to a DVI source.
PROG/NORMAL
Switch
Slide to PROG to upgrade to the latest Kramer firmware via RS-232 or slide to
NORMAL for normal operation.
RS-232 3-pin
Terminal Block
Connector
Connect to a laptop to control
TP
‑
580TD
or perform firmware upgrade.
Connect to a controller device (for example,
SL-240C
) to serially control a remote
device (for example, the DVI OUT acceptor) that is connected to
TP
‑
580RD
.
IR 3.5mm Mini
Jack Connector
Connect to an external infrared emitter / sensor.
12V DC Power
Connector
12V DC connector for powering the unit.