Kramer Electronics Ltd.
TP-580CT
– Connecting TP-580CT
7
Connecting to TP-580CT via RS-232
You can connect to
TP-580CT
via an RS-232 connection
using, for example, a PC.
TP-580CT
features an RS-232 3-pin terminal block connector allowing the RS-232 to control
TP-580CT
.
Connect the RS-232 terminal block on the rear panel of
TP-580CT
to
a PC/controller, as
follows:
From the RS-232 9-pin D-sub serial port connect:
•
Pin 2 to the TX pin on the
TP-580CT
RS-232 terminal block
•
Pin 3 to the RX pin on the
TP-580CT
RS-232 terminal
block
•
Pin 5 to the G pin on the
TP-580CT
RS-232 terminal block
RS-232 Device
TP-580CT
Wiring RJ-45 Connectors
This section defines the HDBT pinout, using a straight pin-to-pin cable with RJ-45 connectors.
For HDBT cables, it is recommended that the cable ground shielding be connected/soldered
to the connector shield.
EIA /TIA 568B
PIN Wire Color
1
Orange / White
2
Orange
3
Green / White
4
Blue
5
Blue / White
6
Green
7
Brown / White
8
Brown
Setting the DIP-Switches
Set DIP-switches. Changes in DIP-switch settings apply immediately.
All DIP-switches are set to OFF (up) by default.
DIP # Description
State
1
IR output
modulation
OFF (up)
– default
IR pass-through is disabled (38KHz modulation to IR
output signal is added).
ON (down)
IR pass-through is enabled.
2
OFF (up)
– default
Normal operation.
ON (down)
FW upgrade via RS-232 is enabled.