TP-578H - Protocol 3000
27
27
Command -
LDEDID
Command Type - System
Command Name
Permission
Transparency
Set:
LDEDID
End User
Public
Get:
-
-
-
Description
Syntax
Set:
Write EDID data from external
application to device
Multi-step syntax (see following steps)
Get:
None
None
Communication Steps (Command and Response)
Step 1: #
LDEDID
␠
dst_type, dest_bitmask, size, safe_mode
␍
Response 1:
~nn@
LDEDID
␠
dst_type, dest_bitmask, size, safe_mode
␠
READY
␍␊
or
~nn@
LDEDID
␠
ERRnn
␍␊
Step 2: If
ready
was received, send EDID_DATA
Response 2:
~ nn@
LDEDID
␠
d
st_type, dest_bitmask
, size
, safe_mode
␠
OK
␍␊
or
~nn@
LDEDID
␠
ERRnn
␍␊
Parameters
dst_type -
EDID destination type (usually input)
dest_bitmask
- bitmap representing destination IDs. Format: 0x********, where * is ASCII presentation of
hex digit. The binary presentation of this number is a bit mask for destinations. Setting ‘1’ means EDID
data has to be copied to this destination
size -
EDID data size
safe_mode
- 0 - Device accepts the EDID as is without trying to adjust
1 - Device tries to adjust the EDID
EDID_DATA - data in protocol packets
Response Triggers
Response is sent to the com port from which the
Set
(before execution)
Notes
When the unit receives the
LDEDID
command it replies with
READY
and enters the special EDID packet
wait mode. In this mode the unit can receive only packets and not regular protocol commands.
If the unit does not receive correct packets for 30 seconds or is interrupted for more than 30 seconds
before receiving all packets, it sends timeout error ~nn@
LDEDID
␠
ERR01
␍␊
and returns to the regular
protocol mode. If the unit received data that is not a correct packet, it sends the corresponding error and
returns to the regular protocol mode.