10
TP-578H - Operating the TP-578H
6
Operating the TP-578H
6.1
The K-Link Setup 4-way DIP-switch
The Setup 4-way dip-switch lets you lock the EDID and set the output timeout.
When a switch is down it is on and when it is up it is off.
Switch
#
Feature
Function
Switch State
1
Lock
EDID
Locks the current EDID in
memory
On
—Lock EDID (down)
Off
—Normal EDID mode
(Default, up)
2
Output
timeout
Turns off the output after
300 seconds when there is
no input signal
On
—Timeout enabled
Off
—Timeout disabled. Output
always on
3
For future use
4
6.2
Locking the EDID
You can lock the current EDID to prevent the EDID from being updated
automatically when a new display device is plugged in.
To lock the current EDID
:
Set DIP-switch 1 to ON
Note
: You can only modify the EDID using Protocol 3000 commands or the EDID
Designer when DIP-switch 1 is on.
6.3
Setting the Output Timeout
You can set the output to be disabled when there is no input detected for 5
minutes or to be always on.
To enable the timeout
:
Set DIP-switch 2 to ON