16 

Table 9: Instruction Codes for the TP-185 

INSTRUCTION 

DEFINITION FOR SPECIFIC INSTRUCTION 

NOTE 

DESCRIPTION 

INPUT 

OUTPUT 

2C 

CONTROLS THE STATUS OF A PORT 

0–close  

1–open 

Output bit: 

O0–O5 = output # or 0 for all outputs 
O6–0 = Tx; 1 = Rx 

1, 2, 4, 5 

2D 

READS THE STATUS OF A PORT 

0–open 

Output bit: 

O0–O5 = output #  
O6–0 = Tx; 1 = Rx 

2, 3, 4, 5 

Note: All values in the table are hexadecimal, unless otherwise stated. 
 
 
NOTES on 

Table 9

 
NOTE 1 – When the PC sends this command, if the instruction is valid the unit replies by sending the PC the same 4 bytes that it was 
sent (except for the first byte where the Destination bit is set high). 
 
NOTE 2 – If O6 = 0 (Tx) – This command defines/reads the definition of the output # (1, 2 or3) to pass the RS-232/Direct command 
from any input. In this case the instruction does not modify previously set output numbers, allowing the setting of multiple outputs for 
the Direct command. If O6 = 1 (Rx), the command defines/reads the definition of the output # (1, 2 or 3) to  pass the reply from the 
output to inputs. In this case, the instruction resets a previously set output number, preventing the setting of multiple outputs for the 
reply.  
 
NOTE 3 – The reply to this command is as follows: The same command and output codes as were sent are returned, and the input is 
assigned the value of the parameter that was read. The reply is per the definitions in command 44.  
 
NOTE 4 – At initial power-on or on reception of command 44 or 45, any received bytes are analyzed to see whether it is a command 44 
or 45. If not, it is transmitted to the output based on the existing setup. If the analyzed bytes are a command 44 or 45, the unit waits for 
the other 3 bytes and interprets them as a Protocol 2000 command. The command is executed if relevant to this machine number or 
discarded if not. 
 
NOTE 5 – This command works only when the unit is configured for Software mode.  
  

Table 10: Sample TP-185 Control Commands 

Command 

Description 

Reply 

2C 80 80 81 

Close all output ports for direct command 

6C 80 80 81 

2C 80 C0 81 

Close all output ports for reply command 

6C 80 C0 81 

2C 81 82 81 

Open port 2 for direct command 

6C 81 82 81 

2C 81 C1 81 

Open port 1 for reply command 

6C 81 C1 81 

2D 80 81 81 

Check status of port 1 for direct command. Port is closed 

6D 80 81 81 

2D 80 82 81 

Check status of port 2 for direct command. Port is open 

6D 81 82 81 

2D 80 C1 81 

Check status of port 1 for reply command. Port is open 

6D 81 C1 81 

2D 80 C2 81 

Check status of port 2 for reply command. Port is closed 

6D 80 C2 81 

Содержание TP-185

Страница 1: ...Kramer Electronics Ltd USER MANUAL Model TP 185 8 Channel UXGA Audio RS 232 to CAT 5 Transmitter...

Страница 2: ...he Reply Feature 10 7 1 3 Setting the Reply Source or Machine Number 11 7 1 4 Setting the RS 232 RS 485 Baud Rate DIP switches 12 7 1 5 Selecting Hardware Software Mode 12 8 Wiring the Twisted Pair RJ...

Страница 3: ...3 Software Mode RS 485 Machine Number DIP switch Setting 11 Table 4 Serial Port Baud Rate DIP switch Setting 12 Table 5 UTP Connector Pinout 13 Table 6 Technical Specifications of the TP 185 14 Table...

Страница 4: ...package includes the following items TP 185 8 Channel UXGA Audio RS 232 to CAT 5 Transmitter Power cord2 rack ears and this user manual3 2 Getting Started We recommend that you Unpack the equipment ca...

Страница 5: ...KRAMER SIMPLE CREATIVE TECHNOLOGY Getting Started 2 2 1 Quick Start This quick start chart summarizes the basic setup and operation steps...

Страница 6: ...quality due to poor matching and elevated noise levels often associated with low quality cables Avoid interference from neighboring electrical appliances that may adversely influence signal quality a...

Страница 7: ...XGA Audio RS 232 to CAT 5 Transmitter 4 4 Defining the TP 185 8 Channel UXGA Audio RS 232 to CAT 5 Transmitter Figure 1 and Table 1 define the front and rear panels of the TP 185 8 Channel UXGA Audio...

Страница 8: ...etermines the serial port baud rate see Section 7 1 4 Hardware Software DIP switch 8 Determines whether the data transmission path is set by software or hardware see Section 7 1 5 7 AC Mains Connector...

Страница 9: ...KRAMER SIMPLE CREATIVE TECHNOLOGY Installing the TP 185 in a Rack 6 5 Installing the TP 185 in a Rack This section describes what to do before installing in a rack and how to rack mount the TP 185...

Страница 10: ...e TP 185 To connect1 the TP 185 as illustrated in the example2 in Figure 2 Figure 2 Connecting the TP 185 8 Channel UXGA Audio RS 232 to CAT 5 Transmitter 1 You do not need to connect all inputs and o...

Страница 11: ...232 device 3 Connect the RS 232 G pin on the TP 185 to pin 5 9 pin D sub on the RS 232 device 6 3 Connecting to the TP 185 via an RS 485 Connection You can operate the TP 185 via the RS 485 port from...

Страница 12: ...TP 185 to the RS 485 terminal block of the second TP 185 and so on see Section 6 3 2 Set each TP 185 Machine number to be a unique number see connecting all the TP 185 units via the RS 485 terminal b...

Страница 13: ...DIP switch requires that you cycle power on the TP 185 7 1 1 Setting the RS 485 Bus Termination The DIP switch sets the RS 485 bus termination Only the first and last physical device on the RS 485 bus...

Страница 14: ...m output 2 ON OFF OFF Reply is taken from output 3 OFF ON OFF Reply is taken from output 4 ON ON OFF Reply is taken from output 5 OFF OFF ON Reply is taken from output 6 ON OFF ON Reply is taken from...

Страница 15: ...5 6 7 1200 OFF OFF OFF 19200 OFF OFF ON 2400 ON OFF OFF 38400 ON OFF ON 4800 OFF ON OFF 57600 OFF ON ON 9600 default ON ON OFF 115200 ON ON ON 7 1 5 Selecting Hardware Software Mode DIP switch 8 sets...

Страница 16: ...n The TP 185 differentiates between the two types of commands and acts accordingly The sequence is as follows 1 Set destination path for command 2 Set return path 3 Send end user command sequence 8 Wi...

Страница 17: ...ANDWIDTH AUDIO 20Hz to 20kHz 0 5dB S N RATIO AUDIO 80dB TOTAL GAIN Audio 0dB COUPLING Audio AC AUDIO THD NOISE Audio 0 03 POWER CONSUMPTION 100 240V AC 16VA OPERATING TEMPERATURE 0 to 55 C 32 to 131 F...

Страница 18: ...efined as 1 I6 I0 INPUT When switching ie instruction codes 1 and 2 the INPUT 7 bits is set as the input number which is to be switched Similarly if switching is done via the machine s front panel the...

Страница 19: ...ple outputs for the reply NOTE 3 The reply to this command is as follows The same command and output codes as were sent are returned and the input is assigned the value of the parameter that was read...

Страница 20: ......

Страница 21: ...REV 1 For the latest information on our products and a list of Kramer distributors visit www kramerelectronics com where updates to this user manual may be found We welcome your questions comments and...

Отзывы: