background image

 

TBUS-201xl - Installing the TBUS-201xl 

 

Installing the TBUS-201xl  

To install the 

TBUS-201xl

 perform the following steps: 

1.  Cut an opening in the table (see 

Section 

 5.1

). 

2.  Install the power socket (see 

Section 

 5.2

). 

3.  Insert the 

TBUS-201xl

 through the cut-out opening (see 

Section 

 5.3

). 

4.  Connect the cables (see 

Section 

 5.4

). 

5.1 

Cutting an Opening 

The metal cutout template (supplied) defines the surface you have to cut out to 

install your 

TBUS-201xl

 

The thickness of the table should be 3in (76mm) or less. 

To cut an opening in the table: 

1.  Before cutting the opening, confirm the dimensions of the cutout template 

and make sure that they have not changed. 

2.  Place the included cut out template (that is included with your 

TBUS-201xl

on the surface of the table exactly where you want to install the  

TBUS-201xl

.  

3.  Attach the template to the table with the included screws (if using the cut out 

template). 

4.  Following the 

inside

 edge of the template, cut a hole in the table surface 

with a sabre or keyhole saw according to the dimensions shown in 

Figure 4

 

(not to scale). 

i

Содержание TBUS-201xl

Страница 1: ...KRAMER ELECTRONICS LTD USER MANUAL MODEL TBUS 201xl Pop up Table Connection Bus P N 2900 300292 Rev 2...

Страница 2: ......

Страница 3: ...tting an Opening 9 5 2 Installing the Power Socket 11 5 3 Inserting the TBUS 201xl through the Cut Out Opening 12 5 4 Connecting the Cables 12 6 Technical Specifications 13 Figures Figure 1 TBUS 201xl...

Страница 4: ...now appear in 14 groups that are clearly defined by function GROUP 1 Distribution Amplifiers GROUP 2 Switchers and Routers GROUP 3 Control Systems GROUP 4 Format Standards Converters GROUP 5 Range Ext...

Страница 5: ...only good quality connection cables we recommend Kramer high performance high resolution cables to avoid interference deterioration in signal quality due to poor matching and elevated noise levels oft...

Страница 6: ...lected and recycled To comply with the WEEE Directive Kramer Electronics has made arrangements with the European Advanced Recycling Network EARN and will cover any costs of treatment recycling and rec...

Страница 7: ...e in Figure 1 shows the TBUS 201xl in a table or podium top with a universal power socket Figure 1 TBUS 201xl Pop up Table Connection Bus In addition the TBUS 201xl is Easily opened and closed by pres...

Страница 8: ...unction 1 Black anodized or brushed anodized aluminum semi automatic lid Covers the connecting surface leaving the table surface neat and tidy 2 Connecting Surface See Section 4 1 3 Outer Rim Fits ove...

Страница 9: ...the table surface 12 Power Connector Lock Secures the power cable so it does not accidently disconnect when opening the lid 13 Pneumatic Piston Enables automatic lifting and smooth closing of the lid...

Страница 10: ...Hz 5A Maximum 5A per power outlet Fully compatible with power plugs in the UK India Italy and Denmark as well as with the 2 prong Europlug Partially compatible if the polarity is reversed with plugs i...

Страница 11: ...A 80 000052 100 240V AC 50 60Hz 5A Maximum 5A per power outlet Brazil TS 201BR 80 000051 100 240V AC 50 60Hz 5A Maximum 5A per power outlet Switzerland TS 201CH 80 000049 100 240V AC 50 60Hz 5A Maximu...

Страница 12: ...your TBUS 201xl The thickness of the table should be 3in 76mm or less To cut an opening in the table 1 Before cutting the opening confirm the dimensions of the cutout template and make sure that they...

Страница 13: ...o scale 5 Unscrew and remove the template from the surface of the table and clean the table surface Take care not to damage the table If needed you can download a full scale template from our Web site...

Страница 14: ...tall the power socket 1 Close the TBUS 201xl lid 2 Carefully insert the power socket housing so that the power socket fits into the power socket opening on the connecting surface and the four standoff...

Страница 15: ...e and place them into the support clamp late slits at the desired height on both the front and rear sides of the unit 3 Make sure that the upper outer rim is situated parallel to the edge of the table...

Страница 16: ...Italy 100 240V AC 50 60Hz 5A Maximum 5A per power outlet Australia 100 240V AC 50 60Hz 5A Maximum 5A per power outlet Israel 220V AC 50 60Hz 5A Maximum 5A per power outlet South Africa 220V AC 50 60Hz...

Страница 17: ......

Страница 18: ...sit our Web site where updates to this user manual may be found We welcome your questions comments and feedback Web site www kramerelectronics com E mail info kramerel com SAFETY WARNING Disconnect th...

Отзывы: