background image

Overview 

 

3  Overview 

The 

TBUS-2

 is a furniture-mounted connection bus that is easily installed into 

a table or podium top. The 

TBUS-2

 lets you connect any equipment to the 

room’s presentation system installations via cable access or passive interfaces. 

When not in use, you can lower the 

TBUS-2

 flush into the table. The example 

in Figure 1 shows the TBUS-2 in a table or podium top with a power socket 

suitable for the US.  

 

Figure 1: TBUS-2 Table Connection Bus 

In addition, the 

TBUS-2 

is: 

 

Easily opened and closed by pressing down gently on the lid

1

 

 

Modular in design, letting you tailor it according to your needs

2

 

 

Available with different power outlet connections

3

  

 

 

                                                       

 

1 Due to its tilting angular construction, pneumatic lift and mechanical latching mechanism, it can be raised (when in use) or 
lowered (when not in use) 
2 The complete list of Kramer inserts, for designing the Connecting Surface, can be found on our Web site at 
http://www.kramerelectronics.com 
3 Suitable for Australia, Belgium and France, Germany and the EU, Italy, South Africa, the UK and the US 

Содержание TBUS-2

Страница 1: ...Kramer Electronics Ltd USER MANUAL Model TBUS 2 ...

Страница 2: ...ut Opening 8 5 3 Installing the Required Kramer Inserts 8 6 Technical Specifications 9 Figures Figure 1 TBUS 2 Table Connection Bus 3 Figure 2 TBUS 2 Table Connection Bus Side View 5 Figure 3 TBUS 2 Connecting Surface 6 Figure 4 TBUS 2 Power Sockets 6 Figure 5 Cutout Dimensions 7 Tables Table 1 TBUS 2 Table Connection Bus Features 5 Table 2 TBUS 2 Connecting Surface Features 6 Table 3 Technical Sp...

Страница 3: ... 2 Getting Started We recommend that you Unpack the equipment carefully and save the original box and packaging materials for possible future shipment Review the contents of this user manual Use Kramer high performance high resolution cables3 2 1 Quick Start This Quick start chart summarizes the basic steps when connecting a TBUS 2 1 GROUP 1 Distribution Amplifiers GROUP 2 Video and Audio Switcher...

Страница 4: ...KRAMER SIMPLE CREATIVE TECHNOLOGY Getting Started 2 ...

Страница 5: ...igure 1 TBUS 2 Table Connection Bus In addition the TBUS 2 is Easily opened and closed by pressing down gently on the lid1 Modular in design letting you tailor it according to your needs2 Available with different power outlet connections3 1 Due to its tilting angular construction pneumatic lift and mechanical latching mechanism it can be raised when in use or lowered when not in use 2 The complete...

Страница 6: ... low quality cables Avoid interference from neighboring electrical appliances that may adversely influence signal quality and position your Kramer TBUS 2 away from moisture excessive sunlight and dust Never place fingers inside the opening on each side of the unit This could cause serious injury because of the sharp edges inside the TBUS 2 Do not place heavy objects on top of the TBUS 2 Do not use...

Страница 7: ...ace leaving the table surface neat and tidy 3 Outer Rim Fits over the table surface 4 Support Bracket Supports the table securing screw two sets 5 Table Securing Screw Tighten to secure the unit to the table surface two sets 6 Support Bracket Grooves Hold the support bracket at the required height four on each side 7 Pneumatic Lift Enables smooth lifting and closing of the lid 8 Mechanical Latchin...

Страница 8: ...nk Plates Six blank covers that can be replaced with Kramer inserts as required see section 5 3 2 Power Sockets 1 Suitable for US power requirements In addition to the US power socket the TBUS 2 is also available with other types of power sockets as illustrated in Figure 4 Australia UK US Belgium France Germany EU South Africa Italy Figure 4 TBUS 2 Power Sockets 1 Also available with other types o...

Страница 9: ... be downloaded from our Web site1 6 03 156 13mm VERIFY ALL DIMENSIONS TO ENSURE THAT THIS PRINT IS 1 TO 1 SCALE MEASURE WITH A RULER inch cm CUT TO THE OUTSIDE OF THE LINE 9 470 240 54mm FRONT FRONT 4x R 500 R12 70mm inch cm MEASURE WITH A RULER Figure 5 Cutout Dimensions The thickness of the table should be 3 or less Before cutting the opening confirm the dimensions and make sure that the specifi...

Страница 10: ...ected the unit to mains power and connected the proper cables you may use the unit 5 3 Installing the Required Kramer Inserts You can install the Kramer inserts before or after installing the TBUS 2 By default the mounting surface includes a power socket different power sockets are available see Figure 4 and six blank plates for optional video audio telephone and network connectors Any of the Kram...

Страница 11: ...240V AC 50 60 Hz 5A per connector Italy 220 240V AC 50 60 Hz 5A per connector POWER SOURCE AC power limits Australia 220 240V AC 50 60 Hz 5A per connector DIMENSIONS Including the outer rim 25 3cm x 16 6cm x 18 4cm 9 97 x 6 53 x 7 25 W D H Without the outer rim 24cm x 15 6cm x 18 4cm 9 47 x 6 03 x 7 25 W D H WEIGHT 1 15kg 2 53lbs approx ACCESSORIES Power cord OPTIONS Kramer inserts and interfaces2...

Страница 12: ...ect fire water lightning orother acts of nature ii Product modification or failure tofollowinstructions suppliedwith theproduct iii Repairorattemptedrepairby anyonenot authorized byKramer iv Anyshipment ofthe product claims must bepresentedtothe carrier v Removalorinstallationofthe product vi Anyother cause whichdoes not relateto aproduct defect vii Cartons equipment enclosures cables or accessori...

Страница 13: ...For the latest information on our products and a list of Kramer distributors visit our Web site www kramerelectronics com where updates to this user manual may be found We welcome your questions comments and feedback Caution Safety Warning Disconnect the unit from the power supply before opening servicing ...

Отзывы: