![Kramer SL-280 Скачать руководство пользователя страница 46](http://html1.mh-extra.com/html/kramer/sl-280/sl-280_user-manual_2000924046.webp)
Kramer Electronics Ltd.
SL-280 – Protocol 3000
44
TIME-SRV
Functions
Permission
Transparency
Set:
TIME-SRV
Administrator
Public
Get:
TIME-SRV?
End User
Public
Description
Syntax
Set:
Set time server
#
TIME-SRV
␠
mode,time_server,time_server_sync_hour
␍
Get:
Get time server
#
TIME-SRV?
␍
Response
~nn
@
TIME-SRV
␠
mode,time_server,time_server_sync_hour,server_status
␍␊
Parameters
mode
–
0
(OFF),
1
(ON)
time_server
– time server IP address or hostname. IP must be, in the following format:
xxx.xxx.xxx.xxx
time_server_sync_hour
– not in use:
0
server_status
–
ON/OFF
Response Triggers
Notes
This command sets up the NTP server.
Example
Set time server with IP address of 128.138.140.44 to ON:
#TIME-SRV
1,
128.138.140.44,0
<CR>