RC-43T - Connecting the RC-43T
9
5.1
K-NET Wiring
The K-NET connector on the
RC-43T
must be connected to a room controller via a
four wire cable as shown in
Figure 5
.
Figure 5: RC-43T K-Net Wiring
Note
: The
RC-43T
is always device ID 2 on the K-NET bus and cannot be
changed.
To connect the RC-43T to a room controller:
Connect pin 1 on the K-NET connector to pin 1 on the room controller K-NET
connector (+12V to +12V)
Connect pin 2 on the K-NET connector to pin 2 on the room controller K-NET
connector (A to A)
Connect pin 3 on the K-NET connector to pin 3 on the room controller K-NET
connector (B to B)
Connect pin 4 on the K-NET connector to pin 4 on the room controller K-NET
connector (G to G)
5.2
Terminating the K-NET Bus
The devices at both ends of the K-NET bus must be terminated.