– Using Embedded Web Pages 

23 

 

Using the Logs Page 

The Logs page allows you to: 

  View current logs 

  Configure the logs 

  Filter the logs 

 

Figure 23: Logs Page 

The display may not update automatically. Click Refresh to update the display. 

Use the Log Filter check-boxes to select which events to display from the log. Use the Log 
Config check-boxes to select which events are recorded. 

Содержание FC-7P

Страница 1: ...P N 2900 300615 Rev 3 www kramerAV com USER MANUAL MODEL FC 7P Ethernet Gateway GPIO Relay...

Страница 2: ...ernet 10 Using Embedded Web Pages 13 Browsing FC 7P Web Pages 13 Setting Device Name and Time Functions 15 Setting Communication Parameters 16 Setting GPIO Port Parameters 17 Setting Relay Port Status...

Страница 3: ...poor matching and elevated noise levels often associated with low quality cables Do not secure the cables in tight bundles or roll the slack into tight coils Avoid interference from neighboring elect...

Страница 4: ...I O Ports Remote IP Based control of devices connected to the control gateway dual function I O ports with selectable port configuration to bidirectional GPIO or relay control Multiple IP Connected Cl...

Страница 5: ...discovery over the network as the FC 7P is set to be a DHCP client by default You can use the Kramer LAN Configurator software to discover devices that are attached to the network including the FC 7P...

Страница 6: ...ay The default setting is port 1 GPIO up and port 2 relay down 4 ON LED Lights green when the unit is on 5 Port 1 I O 3 pin Terminal Block Port 1 terminal block port connects to two GPIO ports or two...

Страница 7: ...y open Port 1 Normally open Port 2 Port IO Function Terminal Block Connections IO Port Default TCP Default Port P1 P2 Transmission Output Activity LEDs P1 white P2 blue Comment G P1 P2 GPIO Ground IO1...

Страница 8: ...P address that was automatically assigned to the FC 7P To discover the IP address of FC 7P use K LAN Configurator available for download from our website at www kramerav com To browse the FC 7P Web UI...

Страница 9: ...Status on page 20 Here you can set the relays on or off 12 If required click Security see Activating Security on page 21 to browse to the Security page 13 Click ON to activate security The user name a...

Страница 10: ...vironment e g maximum ambient temperature air flow is compatible for the device Avoid uneven mechanical loading Appropriate consideration of equipment nameplate ratings should be used for avoiding ove...

Страница 11: ...for example a sensor to terminal block 1 pin P1 or P2 according to the connections shown in table below 3 Set DIP switch 2 down to select relay Connect a relay controlled device for example a project...

Страница 12: ...instructions Connecting the Ethernet Port Directly to a PC You can connect the Ethernet port of the FC 7P directly to the Ethernet port on your PC using a crossover cable with RJ 45 connectors This ty...

Страница 13: ...ies window relevant to your IT system appears as shown in Figure 7 or Figure 8 Figure 7 Internet Protocol Version 4 Properties Window Figure 8 Internet Protocol Version 6 Properties Window 6 Select Us...

Страница 14: ...o a Device To connect the GPIO port on the FC 7P to a device Connect the G pin on the GPIO port to the ground connection on the device Connect the S pin on the GPIO port to the signal positive connect...

Страница 15: ...n Connecting via Ethernet on page 10 2 Ensure that your browser is supported see Technical Specifications on page 26 Browsing FC 7P Web Pages To browse the Web UI 1 Open your Internet browser Type the...

Страница 16: ...he saved preset To save the current configuration 1 Configure the device as required 2 Click Save The Save File window opens 3 Browse to the required location to which to save the file 4 Enter the req...

Страница 17: ...vice is connected to the Internet including the Time Zone and daylight savings time Figure 11 Device Settings Page The FC 7P has a built in clock that can synchronize with a Time Server if required To...

Страница 18: ...arameters The communication page allows you to Turn DHCP for the device on and off Edit the IP settings for static IP addressing The default IP address setting for the device is DHCP Figure 12 Communi...

Страница 19: ...configure the following for each GPIO port Trigger type digital input digital output or analog input Enable and disable the pull up resistor for the digital input and output Set the threshold trigger...

Страница 20: ...passing Max threshold from Low state default 2 2V or low upon passing Min threshold from High state default 0 8V port states according to the user defined voltage threshold levels Pull up resistor ena...

Страница 21: ...stor enabled The port is used for controlling external devices such as room or light switches The external source device determines the voltage output the maximum voltage is 30V DC and the maximum cur...

Страница 22: ...You can select the number of steps the analog input signal will be divided into starting with step 1 and with a maximum of 100 default 8 The voltage of each step is dependent on the number of steps se...

Страница 23: ...e setting must be changed using either the Web UI or a P3000 command To close a relay for example relay 2 1 On the Relay Setting page click Port button 2 to select the second relay The current relay s...

Страница 24: ...tion popup is displayed as shown in Figure 20 Figure 20 Security Confirmation Popup 2 Click OK The Authentication Required popup is displayed as shown in Figure 21 Figure 21 Authentication Required Po...

Страница 25: ...u to View current logs Configure the logs Filter the logs Figure 23 Logs Page The display may not update automatically Click Refresh to update the display Use the Log Filter check boxes to select whic...

Страница 26: ...Kramer Electronics Ltd FC 7P Using Embedded Web Pages 24 Kramer Information The About Us page displays the Web UI version and the Kramer company details Figure 24 About Us Page...

Страница 27: ...eset the device to its factory default settings 1 Turn off the power to the device 2 Press and hold the Reset button on the front panel 3 Turn on the power to the device while holding down the Reset b...

Страница 28: ...ity 10 to 90 RHL non condensing Regulatory Compliance Vibration ISTA 1A in carton International Safe Transit Association Safety CE Environmental RoHs WEEE General Enclosure type Aluminum Net dimension...

Страница 29: ...HCP and the IP address are set to the values shown below Ethernet DHCP Off IP Address 192 168 1 39 Host Name FC 7 xxxx where xxxx are the last four digits of the serial number of the device Subnet Mas...

Страница 30: ...Builder Kramer software K Config Kramer configuration software All the examples provided in this section are based on using the K Config software You can enter commands directly using terminal commun...

Страница 31: ...CR Simple Command Command string with only one command without addressing Start Body Delimiter Command SP Parameter_1 Parameter_2 CR Command String Formal syntax with commands concatenation and addre...

Страница 32: ...acters for specific commands Parameters are separated by commas A string can contain more than one command Commands are separated by a pipe character Message string Every command entered as part of a...

Страница 33: ...on some characters require special coding such as X Refer to the controller manual Command Forms Some commands have short name syntax in addition to long name syntax to allow faster typing The respons...

Страница 34: ...tion GPIO STATE Set get HW GPIO state GPIO STEP Set get HW GPIO step GPIO THR Set get HW GPIO threshold voltage GPIO VOLT Get HW GPIO voltage level HELP List of commands LOGIN Set get protocol permiss...

Страница 35: ...Protocol 3000 Detailed Commands This section lists the detailed commands applicable to the FC 7P Functions Permission Transparency Set End User Public Get Description Syntax Set Protocol handshaking...

Страница 36: ...Num portType ETHPort ETH_rep_en TCP_keep_alive_timing Get Get tunneling port routing COM ROUTE COM_Num Response nn COM ROUTE COM_Num portType ETHPort ETH_rep_en TCP_keep_alive_timing Parameters COM_Nu...

Страница 37: ...1 COM port sends replies to new clients 0 COM port does not send replies to new clients Timeout Keep alive timeout in seconds 1 to 3600 Response Triggers Notes K Config Example Add COM1 port as TCP po...

Страница 38: ...Delete a file named test DEL test 0x0D DIR Functions Permission Transparency Set DIR Administrator Public Get Description Syntax Set List files in device DIRCR Get Response Multi line nn DIRCR LF file...

Страница 39: ...ansparency Set Get ETH TUNNEL Administrator Internal Description Syntax Set Get Get parameters for an open tunnel ETH TUNNEL TunnelId Response nn ETH TUNNEL TunnelId ComNum PortType EthPort EthIp Remo...

Страница 40: ...command deletes all user data from the device The deletion can take some time Your device may require powering off and powering on for the changes to take effect K Config Example FACTORY 0x0D FORMAT F...

Страница 41: ...Triggers K Config Example FS FREE 0x0D GET Functions Permission Transparency Set Get GET Administrator Public Description Syntax Set Get Get file GETSPfile_nameCR Response Multi line nn GETSPfile_name...

Страница 42: ...alog input with pullup disabled GPIO CFG 2 0 0 0 0x0D GPIO STATE Functions Permission Transparency Set GPIO STATE End User Public Get GPIO STATE End User Public Description Syntax Set Set HW GPIO stat...

Страница 43: ...l mode the response is 2 In analog mode the response is 1 to 100 In other modes an error is returned K Config Example Set GPIO 2 step 1 to 50 GPIO STEP 2 1 50 0x0D GPIO THR Functions Permission Transp...

Страница 44: ...nd is not available in digital out mode K Config Example GPIO VOLT 1 0x0D HELP Functions Permission Transparency Set Get HELP End User Public Description Syntax Set Get Get command list or help for sp...

Страница 45: ...iggers Notes When the permission system is enabled LOGIN enables running commands with the User or Administrator permission level When set login must be performed upon each connection The permission s...

Страница 46: ...is only set after restarting the device K Config Example MACH NUM 4 0x0D MODEL Functions Permission Transparency Set Get MODEL End User Public Description Syntax Set Get Get device model MODEL CR Res...

Страница 47: ...t the beginning or end Response Triggers Notes The machine name is not the same as the model name The machine name is used to identify a specific machine or a network in use with DNS feature on K Conf...

Страница 48: ...able using the NAME command You can also get an assigned IP by direct connection to USB or RS 232 protocol port if available Consult your network administrator for correct settings K Config Example En...

Страница 49: ...in the following format xxx xxx xxx xxx Response Triggers Notes Consult your network administrator for correct settings K Config Example Set the IP address to 192 168 1 39 NET IP 192 168 001 039 0x0D...

Страница 50: ...ettings Notes K Config Example Set the subnet mask to 255 255 0 0 NET MASK 255 255 000 000 0x0D PASS Functions Permission Transparency Set PASS Administrator Public Get PASS Administrator Public Descr...

Страница 51: ...unlock Response Triggers Notes K Config Example Lock port 3 PORT LOCK 3 1 0x0D PORT TYPE Functions Permission Transparency Set PORT TYPE End User Public Get PORT TYPE End User Public Description Synta...

Страница 52: ...nse nn RELAY STATE RelayNumber RelayState Parameters RelayNumber relay number 1 2 RelayState relay state 0 open 1 close Response Triggers Notes K Config Example Close relay 2 RELAY STATE 2 1 0x0D PROT...

Страница 53: ...t was locked disconnect and reconnect the cable to reopen the port K Config Example RESET 0x0D SECUR Functions Permission Transparency Set SECUR Administrator Public Get SECUR Not Secure Public Descri...

Страница 54: ...Functions Permission Transparency Set TIME Administrator Public Get TIME End User Public Description Syntax Set Set device time and date TIMESPday_of_week date timeCR Get Get device time and date TIM...

Страница 55: ...me is in effect TIME command sets the device time without considering these settings K Config Example Set the time offset to GMT 2 standard time TIME LOC 2 0 0x0D TIME SRV Functions Permission Transpa...

Страница 56: ...ncy Set Get VERSION End User Public Description Syntax Set Get Get firmware version number VERSION CR Response nn VERSIONSPfirmware_versionCR LF Parameters firmware_version XX XX XXXX where the digit...

Страница 57: ...ized dealer from which it was purchased or any other party authorized to repair Kramer Electronics products this product must be insured during shipment with the insurance and shipping charges prepaid...

Страница 58: ...RNING Disconnect the unit from the power supply before opening andservicing For the latest information on our products and a list of Kramer distributors visit our Web site where updates to this user m...

Отзывы: