16
FC-42 - Communication Protocol
The following table defines the global parameter data:
Global Parameter Number
Global Parameter Data
Description
#
Panel Lock
00
0 - Off (Default)
1 - On
Machine Address
01
0,1
Setup Number
02
0 - 15
Free Run Mode
03
0 - Black Screen (Default)
1 - Blue Screen
Input Standard
(Read Only)
(AUTO Mode Only)
08
0 - 720p/60
1 - 720p/59
2 - 720p/50
3 - 1080i/60
4 - 1080i/59
5 - 1080i/50
6 - 1080p/30
7 - 1080p/29
8 - 1080p/25
9 - 1080p/24
A - 1080p/23
B - 1080sf/30
C - 1080sf/29
D - 1080sf/25
E - 1080sf/24
F -1080sf/23
10 - Not Identified
11 - Not Identified
Presence of Input Signal
(Read Only)
09
0 - Input Signal is Present
1 - No Input Signal
NOTE 1
: These commands are sent by the unit also when Local / Global parameters are changed via the front panel or
as a result of execution of any other command.
NOTE 2
: If it is necessary merely to save adjusted parameters in initial setup number (no setup number change), then
the value of byte3 must be equal to the value of byte2 - initial setup number.
NOTE 3
: The reply to the Identify Machine command shows the machine name
- 1st byte: 0x7d
- 2nd byte: 0x80 + 0x00 (0 dec)
- 3rd byte: 0x80 + 0x29 (41 dec) - for the unit FC-42
- 4th byte: 0x98
NOTE 4
: The reply to the Identify Firmware command shows the firmware version as
- 1st byte: 0x7d
- 2nd byte: 0x80 + the version number prior to decimal point
- 3rd byte: 0x80 + the version number following the decimal point
- 4th byte: 0x98
For example, for version 3.5, the reply would be 0x7d, 0x83, 0x85, 0x98.