Kramer Electronics Ltd.
FC
‑
404NET
– Protocol 3000 Commands
19
RESET
Functions
Permission
Transparency
Set:
RESET
Administrator
Public
Get:
-
-
-
Description
Syntax
Set:
Reset device
#RESET
CR
Get:
-
-
Response
~
nn
@RESET
SP
OK
CR LF
Parameters
Response Triggers
Notes
To avoid locking the port due to a USB bug in Windows, disconnect USB connections immediately after running this command. If the
port was locked, disconnect and reconnect the cable to reopen the port.
SN?
Functions
Permission
Transparency
Set:
-
-
-
Get:
SN?
End User
Public
Description
Syntax
Set:
-
-
Get:
Get device serial number
#SN?
CR
Response
~
nn
@SN
SP
serial_number
CR LF
Parameters
serial_number
– 14 decimal digits, factory assigned
Response Triggers
Notes
For new products with 14 digit serial numbers, use only the last 11 digits
VERSION?
Functions
Permission
Transparency
Set:
-
-
-
Get:
VERSION?
End User
Public
Description
Syntax
Set:
-
-
Get:
Get firmware version number
#VERSION?
CR
Response
~
nn
@VERSION
SP
firmware_version
CR LF
Parameters
firmware_version
– XX.XX.XXXX where the digit groups are: major.minor.build version
Response Triggers
Notes