Kramer Electronics Ltd.
FC
‑
404NET
– Protocol 3000 Commands
18
FACTORY
Functions
Permission
Transparency
Set:
FACTORY
End User
Public
Get:
-
-
-
Description
Syntax
Set:
Reset device to factory default configuration
#FACTORY
CR
Get:
-
-
Response
~
nn
@FACTORY
SP
OK
CR LF
Parameters
Response Triggers
Notes
This command deletes all user data from the device. The deletion can take some time.
Your device may require powering off and powering on for the changes to take effect.
MODEL?
Functions
Permission
Transparency
Set:
-
-
-
Get:
MODEL?
End User
Public
Description
Syntax
Set:
-
-
Get:
Get device model
#MODEL?
CR
Response
~
nn
@MODEL
SP
model_name
CR LF
Parameters
model_name
– string of up to 19 printable ASCII chars
Response Triggers
Notes
This command identifies equipment connected to Step-in master products and notifies of identity changes to the connected
equipment. The Matrix saves this data in memory to answer REMOTE-INFO requests
PROT-VER?
Functions
Permission
Transparency
Set:
-
-
-
Get:
PROT-VER?
End User
Public
Description
Syntax
Set:
-
-
Get:
Get device protocol version
#PROT-VER?
CR
Response
~
nn
@PROT-VER
SP
3000:version
CR LF
Parameters
version
– XX.XX where X is a decimal digit
Response Triggers
Notes