Kramer Electronics Ltd.
DIP-31
– Protocol 3000
39
BUILD-DATE
Functions
Permission
Transparency
Set:
-
-
-
Get:
BUILD-DATE?
End User
Public
Description
Syntax
Set:
-
-
Get:
Get device build date
#
BUILD-DATE?
CR
Response
~nn@
BUILD-DATE
SP
date
SP
time
CR LF
Parameters
date
–
Format:
YYYY/MM/DD
where
YYYY
= Year,
MM
= Month,
DD
= Day
time
–
Format:
hh:mm:ss
where
hh
= hours,
mm
= minutes,
ss
= seconds
Response Triggers
Notes
K-Config Example
“#BUILD
-
DATE?”,0x0D
FACTORY
Functions
Permission
Transparency
Set:
FACTORY
End User
Public
Get:
-
-
-
Description
Syntax
Set:
Reset device to factory default configuration
#
FACTORY
CR
Get:
-
-
Response
~nn@
FACTORY
SPOKCR LF
Parameters
Response Triggers
Notes
This command deletes all user data from the device. The deletion can take some time.
Your device may require powering off and powering on for the changes to take effect.
K-Config Example
“#FACTORY”,0x0D