We recommend that you:  

 

Unpack the equipment carefully and save the original box and packaging 
materials for possible future shipment  

 

Review the contents of this user manual   

 

 

 

Go to 

http://www.kramerelectronics.com

 to check for up-to-date 

user manuals, application programs, and to check if firmware 
upgrades are available (where appropriate).  

2.1 

Achieving the Best Performance  

To achieve the best performance:  

 

Use only good quality connection cables (we recommend Kramer high-
performance, high-resolution cables) to avoid interference, deterioration in 
signal quality due to poor matching, and elevated noise levels (often 
associated with low quality cables)  

 

Do not secure the cables in tight bundles or roll the slack into tight coils  

 

Avoid interference from neighboring electrical appliances that may adversely 
influence signal quality    

 

Position your 

905xl 

away from moisture, excessive sunlight and dust  

 

This equipment is to be used only inside a building. It may only be 
connected to other equipment that is installed inside a building

 

2.2 

Safety Instructions  

 

 

 

 

Caution: 

There are no operator serviceable parts inside the unit 

Warning: 

Use only the power cord that is supplied with the unit  

Warning: 

Do not open the unit. High voltages can cause 
electrical shock! Servicing by qualified personnel only 

Warning: 

Disconnect the power and unplug the unit from the wall 
before installing  

i

!

!

Содержание 905xl

Страница 1: ...KRAMER ELECTRONICS LTD USER MANUAL MODEL 905xl Power Amplifier P N 2900 300196 Rev 3...

Страница 2: ......

Страница 3: ...necting to the 905xl via RS 232 8 7 Operating the 905xl Power Amplifier 9 7 1 Using the Front Panel Buttons 9 7 2 Using the Audio Control Program 9 7 3 Upgrading the Firmware 11 8 Technical Specificat...

Страница 4: ...rly defined by function GROUP 1 Distribution Amplifiers GROUP 2 Switchers and Routers GROUP 3 Control Systems GROUP 4 Format Standards Converters GROUP 5 Range Extenders and Repeaters GROUP 6 Specialt...

Страница 5: ...poor matching and elevated noise levels often associated with low quality cables Do not secure the cables in tight bundles or roll the slack into tight coils Avoid interference from neighboring elect...

Страница 6: ...cted and recycled To comply with the WEEE Directive Kramer Electronics has made arrangements with the European Advanced Recycling Network EARN and will cover any costs of treatment recycling and recov...

Страница 7: ...10A 4 pin terminal block connector In particular the 905xl features An unbalanced stereo input on RCA connectors A balanced stereo input on a terminal block connector Two input selector buttons Volum...

Страница 8: ...nced stereo audio source see Section 6 RIGHT RCA Connector Connect to the right channel of the unbalanced stereo audio source see Section 6 5 INPUT 2 5 pin Terminal Block Audio Input Connect to the le...

Страница 9: ...6 905xl Installing in a Rack 5 Installing in a Rack This section provides instructions for rack mounting the unit...

Страница 10: ...n the power to each device Figure 2 Connecting the 905xl Power Amplifier To connect the 905xl Power Amplifier as illustrated in the example in Figure 2 1 Connect an unbalanced stereo audio source for...

Страница 11: ...he mains electricity not shown in Figure 2 5 If required connect a PC and or controller to the RS 232 port see Section 6 1 6 1 Connecting to the 905xl via RS 232 You can connect to the 905xl via an RS...

Страница 12: ...s the up volume button to increase the volume 2 Press the down volume button to decrease the volume 7 1 2 Muting the Output To mute the output Press the Mute button The button lights and the audio is...

Страница 13: ...tp www kramerelectronics com 2 Connect the 905xl to the correct COM port of the PC see Section 6 3 Open the Audio Control program The Audio Control window appears see Figure 3 4 Select Input 1 or 2 5...

Страница 14: ...905xl Operating the 905xl Power Amplifier 11 7 3 Upgrading the Firmware For instructions on upgrading the firmware see Upgrading the 905xl Firmware Using the FLIP Software...

Страница 15: ...3dB 26kHz S N RATIO 80dB CROSSTALK 120dB 1kHz 111dB 20kHz CONTROLS Bass 15dB to 14dB 100Hz Mid 13 7dB to 13 7dB 1kHz Treble 13 7dB to 13 8dB 10kHz Balance 46 9dB to 0dB Volume 80dB to 32dB 1kHz ADDITI...

Страница 16: ...905xl Default Communication Parameters 13 9 Default Communication Parameters RS 232 Baud Rate 9600 Data Bits 8 Stop Bits 1 Parity None Command Format ASCII Example Switch to Input 1 AUD IN 1 CR...

Страница 17: ...with only one command without addressing Start Body Delimiter Command SP Parameter_1 Parameter_2 CR 10 1 1 2 Command String Formal syntax with command concatenation and addressing Start Address Body D...

Страница 18: ...essage closing character Note A string can contain more than one command Commands are separated by a pipe character Message starting character For host command query For device response Device address...

Страница 19: ...ng The response is always in long syntax 10 1 6 Chaining Commands Multiple commands can be chained in the same string Each command is delimited by a pipe character When chaining commands enter the mes...

Страница 20: ...o bass level TREBLE Set audio treble level TREBLE Read audio treble MIDRANGE Set audio midrange level MIDRANGE Read audio midrange level LOUDNESS Set audio loudness LOUDNESS Read audio loudness MUTE M...

Страница 21: ......

Страница 22: ...sit our Web site where updates to this user manual may be found We welcome your questions comments and feedback Web site E mail www kramerelectronics com info kramerel com P N 2900 300196 Rev 3 SAFETY...

Отзывы: