background image

KRAMER:  SIMPLE CREATIVE TECHNOLOGY

 

Connecting Differential Video Line Amplifier Units 

 

Connecting Differential Video Line Amplifier Units 

You can connect up to five 

123Vxl 

Differential Video Line Amplifier 

units, 

to provide up to 15 outputs, as 

Figure 3

 illustrates. 

To

 

connect up to five 

123Vxl 

Differential Video Line Amplifier 

units: 

1.  Connect the video source to the 

CV IN

 BNC connector on the first unit. 

2.  Connect the 

LOOP

 BNC connector on each unit to the 

CV IN

 BNC 

connector on the next unit in the line, respectively

1

3.  Connect the 

OUT 1

,

 OUT 2 

and

 OUT 3

 BNC connectors on each unit to the 

appropriate video acceptors

2

, as required. 

4.  Release the TERM switch (selecting Hi-Z) on all units, except on the last 

(fifth) unit. Push in the TERM switch on the last (fifth) unit (selecting 
75 ). 

5.  If required, adjust

3

 the output signal level and/or cable compensation 

equalization level on each unit. 

 

Figure 3: Connecting 123Vxl Differential Video Line Amplifier Units 

                                                       

 

1 Connect the LOOP BNC connector on the first unit to the CV IN BNC connector on the second unit. Connect the LOOP 
BNC connector on the second unit to the CV IN BNC connector on the third unit. Connect the LOOP BNC connector on the 
third unit to the CV IN BNC connector on the fourth unit. Connect the LOOP BNC connector on the fourth unit to the CV IN 
BNC connector on the fifth unit. Leave the LOOP BNC connector on the fifth (last) unit unconnected 
2 Connect the OUT 1, OUT 2 and OUT 3 BNC connectors on the first unit to the video acceptors 1, 2 and 3, respectively. 
Connect the OUT 1, OUT 2 and OUT 3 BNC connectors on the second unit to the video acceptors 4, 5 and 6, respectively. 
Connect the OUT 1, OUT 2 and OUT 3 BNC connectors on the third unit to the video acceptors 7, 8 and 9, respectively. 
Connect the OUT 1, OUT 2 and OUT 3 BNC connectors on the fourth unit to the video acceptors 10, 11 and 12, respectively. 
Connect the OUT 1, OUT 2 and OUT 3 BNC connectors on the fifth unit to the video acceptors 13, 14 and 15, respectively 
3 Use a screwdriver to carefully rotate the trimmer, adjusting the appropriate level 

Содержание 123Vx1

Страница 1: ...Kramer Electronics Ltd Preliminary USER MANUAL Model 123Vxl Differential Video Line Amplifier ...

Страница 2: ...rential Video Line Amplifier Units 6 7 Technical Specifications 7 Figures Figure 1 123Vxl Differential Video Line Amplifier 4 Figure 2 Connecting the 123Vxl Differential Video Line Amplifier 5 Figure 3 Connecting 123Vxl Differential Video Line Amplifier Units 6 Tables Table 1 123Vxl Differential Video Line Amplifier Features 4 Table 2 Technical Specifications of the 123Vxl Differential Video Line ...

Страница 3: ...p to three distant monitors The package includes the following items 123Vxl Differential Video Line Amplifier Power adapter 12V DC Input This user manual2 2 Getting Started We recommend that you Unpack the equipment carefully and save the original box and packaging materials for possible future shipment Review the contents of this user manual Use Kramer high performance high resolution cables3 1 G...

Страница 4: ...inherent in long cable runs A Kramer TOOLS enclosure and 12V DC supply voltage To achieve the best performance Use only good quality connection cables1 to avoid interference deterioration in signal quality due to poor matching and elevated noise levels often associated with low quality cables Avoid interference from neighboring electrical appliances that may adversely influence signal quality and ...

Страница 5: ...Overview 3 3 1 Quick Start This quick start chart summarizes the basic setup and operation steps ...

Страница 6: ...Connects to the video acceptor 2 4 OUT 3 BNC Connector Connects to the video acceptor 3 5 CV IN BNC Connector Connects to the video source 6 TERM Hi Z 75 Switch Pushing in selects 75 releasing selects Hi Z 1 7 LOOP BNC Connector For looping to increase output availability2 8 ON LED Illuminates when receiving power 9 GAIN Trimmer Adjusts3 the output signal level for outputs 1 2 and 3 10 EQ Trimmer ...

Страница 7: ... video display 3 3 If necessary connect the LOOP BNC connector to the CV IN BNC connector on an additional 123Vxl unit and release the TERM switch to Hi Z 4 If required adjust2 the output signal level and or cable compensation equalization level 5 Connect a 12V DC power adapter to the power socket and connect the adapter to the mains electricity not shown in Figure 2 Figure 2 Connecting the 123Vxl...

Страница 8: ...eo Line Amplifier Units 1 Connect the LOOP BNC connector on the first unit to the CV IN BNC connector on the second unit Connect the LOOP BNC connector on the second unit to the CV IN BNC connector on the third unit Connect the LOOP BNC connector on the third unit to the CV IN BNC connector on the fourth unit Connect the LOOP BNC connector on the fourth unit to the CV IN BNC connector on the fifth...

Страница 9: ...deo 1Vpp 75 on BNC connectors MAX OUTPUT LEVEL 1 7Vpp BANDWIDTH 3dB 425MHz DIFF GAIN 0 5 DIFF PHASE 0 3 Deg K FACTOR 0 05 S N RATIO 60 3dB CONTROLS Level 1 8dB to 5 6dB EQ 0 to 15dB 5 8MHz 75 termination switch COUPLING AC POWER SOURCE 12V DC 80mA DIMENSIONS 12cm x 7 5cm x 2 5 cm 4 7 x 2 95 x 0 98 W D H WEIGHT 0 3 kg 0 67 lbs approx ACCESSORIES Power supply mounting bracket OPTIONS RK 3T 19 rack a...

Страница 10: ...ightning orotheractsofnature ii Product modification orfailureto followinstructions supplied with theproduct iii Repairorattemptedrepairby anyonenot authorizedbyKramer iv Anyshipment of theproduct claims must bepresentedtothe carrier v Removalorinstallationoftheproduct vi Anyothercause whichdoes not relatetoaproduct defect vii Cartons equipment enclosures cables or accessoriesusedinconjunctionwith...

Страница 11: ...test information on our products and a list of Kramer distributors visit our Web site www kramerelectronics com where updates to this user manual may be found We welcome your questions comments and feedback Caution Safety Warning Disconnect the unit from the power supply before opening servicing PN 2900 001031 Rev 4 ...

Отзывы: