4 Technical data
4.4 Substitute operating data
Unit
013
020
032
052
068
100
Additional maximum values when BEG 44 is used
K2
Pole number
4
8
12
16
20
28
K-factor
[P/l]
2432
1280
468
142
79.6
33.6
Millilitre/pulse
[ml/P]
0.41
0.78
2.14
7.04
12.56
29.76
Pulse frequency
o
f2 (Q
max
)
[Hz]
608
960
1170
1243
1393
1680
o
f2 (Q
rated
)
[Hz]
405
640
780
828
929
1120
o
f2 (Q
min
)
[Hz]
4.1
6.4
7.8
8.3
9.3
11.2
Additional maximum values when BEG 45 is used
K3
Pole number
12
16
26
34
42
48
K-factor
[P/l]
7296
2560
1014
302
167
57.6
Millilitre/pulse
[ml/P]
0.14
0.39
0.99
3.31
5.98
17.36
Pulse frequency
o
f3 (Q
max
)
[Hz]
1824
1920
2535
2640
2927
2880
o
f3 (Q
rated
)
[Hz]
1216
1280
1690
1760
1949
1920
o
f3 (Q
min
)
[Hz]
12.2
12.8
16.9
17.6
19.5
29.2
Observe flow range: If the value drops below Q
min
, refer to the
operating instructions of the associated pick up
Additional maximum values when BEG 53A/BEG 54A is used
K4
Pole number
12
16
26
34
42
73
K-factor
[P/l]
7296
2560
1014
302
167
87.6
Millilitre/pulse
[ml/P]
0.14
0.39
0.99
3.31
5.98
11.42
Pulse frequency
o
f4 (Q
max
)
[Hz]
1824
1920
2535
2643
2923
4380
o
f4 (Q
rated
)
[Hz]
1216
1280
1690
1762
1948
2920
o
f4 (Q
min
)
[Hz]
12.2
12.8
16.9
17.6
19.5
29.2
4.4 Substitute operating data
The following table shows standardized values for the flow rate, temperature and viscosity. These val-
ues can be used at the same time as maximum values without impairing the service life of the flow-
meter. In addition, the operating limits of the corresponding completion, of the sealing material of the
pick up and of the temperature sensor are to be observed.
Unit
013
020
032
052
068
100
Flow rate
o
Q
max
[l/min]
10
30
100
350
700
2000
o
Q
rated
[l/min]
10
30
100
350
700
2000
o
Q
min
[l/min]
0.2
0.6
2.0
7.0
14.0
40.0
Max. pressure
[bar]
420
420
420
420
420
250
Min. temperature - max.
[°C]
-20 ... +120
Min. – max. viscosity
[mm
2
/s]
1 – 200
Tab. 3: Substitute operating data
4.5 Sound pressure level
The sound pressure level of the flowmeters amounts to less than 70 dB(A).
Operating instructions
OIO 08en-GB Edition 2020-01
9