6 Installation, removal and connection
6.5 Installing the EET in the piping
1
2
1.
Remove the screw plug from the sensor bore.
2.
Clean the sensor bore. No foreign bodies should penetrate the flowmeter
2
or piping system.
3.
Select suitable sensor
1
,
Ä
4.
Screw the sensor into the sensor bore as far as it will go, maximum tightening torque 30 Nm.
5.
Connect the sensor cable, observing the connection diagram.
Ä
6.5 Installing the EET in the piping
Personnel qualification:
o
Electrician
Personal protective equipment:
o
Work clothing
Aids:
o
Torque wrench
WARNING
Risk of injury through escaping medium.
Media can be hot, poisonous, combustible and caustic.
► Before installing the sensor, switch off the system and depressurise it.
► Wear personal protective equipment at all times during operation. Pay attention to face protection.
► Collect any escaping medium safely and dispose of it in an environmentally compatible manner in
accordance with the applicable local regulations.
>
4
m
m
1
2
1.
Clean the sensor bore. No foreign bodies should penetrate the flowmeter or piping system
2
.
2.
Select a suitable sensor
1
3.
Screw the sensor into the sensor bore as far as it will go, maximum tightening torque 30 Nm.
4.
Connect the sensor cable, observing the connection diagram.
Ä
Operating instructions
OII 08en-GB Edition 2021-07
11