3 Technical data
3.1 Operating limits
3 Technical data
3.1 Operating limits
The following table shows the operating limits of the temperature sensors that must not be exceeded.
Parameter
Unit
Type
EET 32
EET 33
EET 34
EET 38
Max. operating pressure
[bar]
300
100
Medium temperature min. - max.
[°C]
-50 ... 260
Tab. 2: Operating limits
In addition, the operating limits of the corresponding flowmeter and the additional sensors must be ob-
served.
3.2 Selecting the temperature sensor
Flowmeter
Installation in pipeline
Size
Series
OME
OMG
OMP
13
EET 32
EET 34/EET 38 –
Any temperature sensor
possible
20
EET 32
EET 33
EET 33
32
EET 32
EET 34/EET 38 EET 34/EET 38
52
EET 33
EET 34/EET 38 EET 33
68
–
EET 34/EET 38 –
100
–
EET 34/EET 38 –
140
–
–
–
Operating instructions
OII 08en-GB Edition 2021-07
5