15 Accessories
15.1 Installation
15.1.4
Fixing kit mounting on OME
Fixing kit
Application
Article No.
Suitable for
Mounting on flowmeter
OME
UZA 21
1.2
BEM 300 / BEM 500 / OME-013
UZA 22
1.2
BEM 300 / BEM 500 / OME-020
UZA 24
2
BEM 300 / BEM 500 / OME-032
1
Not suitable for OME with DIN flanges
2
Not suitable for OME with temperature sensor connection
15.1.5
Adapter set for conversion of BEM 4U to BEM 300 / BEM 500
Adapter set
Application
Article No.
Suitable for
o
Mounting in the
control cabinet
o
Conversion of
BEM 4U to
BEM 300 / BEM 500
EGT 23
BEM 300
BEM 500
Scope of delivery:
o
1 sheeting bonded to
seal
o
1 sheeting
Change BEM 4U to BEM 500
Notice
The previously used temperature sensors have to be replaced by temperature sensors with Pt100 out-
put. These temperature sensors are available from KRAL. During conversion, observe setting the tem-
perature sensor units.
Notice
Depending on the sheeting thickness of the control cabinet the supplied screws may have to be re-
placed by longer screws.
1
2
3
4
5
6
1
Electronic unit
5
Sheeting**
2
Front frame*
6
Sealing frame*
3
Sheeting bonded to seal**
7
Screws and wedge lock washers*
4
Control cabinet
*
Included in the scope of delivery of the
BEM 300/BEM 500
**
Adapter set
1.
Remove the BEM 4U.
2.
Slide the front frame
2
and sheeting with seal
3
from the rear onto the electronic unit
1
.
3.
Position the electronic unit in the control cabinet section.
4.
Slide on the sheeting
5
and sealing frame
6
and fasten using the screws and wedge lock
washers
7
.
Operating instructions
OIE 12en-GB Edition 2020-03
43