11 Menu description
11.6 Menu 4: K-factors flowmeter A
11.6 Menu 4: K-factors flowmeter A
o
Entry of the K-factors of the flowmeter A with increasing frequency for the formation of the lineariza-
tion characteristic
o
K-factors, associated frequencies and resulting K-factor, see calibration certificate of the flowmeter
o
Resulting K-factor, also see rating plate of the flowmeter
o
Changes only possible with password
o Ä
Menu item
Description
4.01 K-factor
Volumeter A Point 1
...
4.07 K-factor
Volumeter A Point 7
Example without linearization:
o
Point 1
: Resulting K-factor and frequency at Q
nom
o
Point 2
: Frequency
0
Example linearizion with three points:
o
Point 1
: Any K-factor and associated frequency
o
Point 2
: K-factor and associated frequency in ascending order
o
Point 3
: K-factor and frequency at Q
nom
(highest value)
o
Point 4
: Frequency
0
Note:
The number of linearization points is limited by the input of the frequency 0.
0
. Ensure that the K-
factor and frequency of Q
nom
are entered respectively in the preceding point.
The linearization is extended to 0 Hz or to ∞ Hz via the first or last two linearization points resp. and
mirrored into negative values.
11.7 Menu 5: K-factors flowmeter B
o
Entry of the K-factors of the flowmeter B with increasing frequency for the formation of the lineariza-
tion characteristic
o
K-factors, associated frequencies and resulting K-factor, see calibration certificate of the flowmeter
o
Resulting K-factor, also see rating plate of the flowmeter
o
Changes only possible with password
o Ä
Menu item
Description
5.01 K-factor
Volumeter B Point 1
...
5.07 K-factor
Volumeter B Point 7
Example without linearization:
o
Point 1
: Resulting K-factor and frequency at Q
nom
o
Point 2
: Frequency
0
Example linearizion with three points:
o
Point 1
: Any K-factor and associated frequency
o
Point 2
: K-factor and associated frequency in ascending order
o
Point 3
: K-factor and frequency at Q
nom
(highest value)
o
Point 4
: Frequency
0
Note:
The number of linearization points is limited by the input of the frequency 0.
0
. Ensure that the K-
factor and frequency of Q
nom
are entered respectively in the preceding point.
The linearization is extended to
0
or to ∞Hz via the first or last two linearization points resp. and
mirrored into negative values.
Operating instructions
OIE 12en-GB Edition 2020-03