21
22
• Measurement range: 10Hz ~ 60MHz.
• Input range:
≥
0.2V AC rms (input voltage will increase
as frequency increases).
• Input impedance: 10MΩ
• Maximum input voltage: 250V AC rms.
± 0.3%
Range
Resolution Accuracy
5 – 95%
0.1%
Duty Cycle
Battery Replacement
REMOVE THE TEST LEADS FROM THE METER
BEFORE REMOVING THE BATTERY CASE TO AVOID
ELECTRICAL SHOCK AND INJURY.
WARNING:
1.Replace the batteries once the display shows“ ” to
avoid false readings.
2.Remove test leads and unscrew the battery cover and
remove the cover.
3.Replace the used battery with a new one.
4.Replace the battery cover and tighten the screw.
Maintenance
General Maintenance
• To avoid possible electric shock or personal injury,
repairs or servicing not covered in this manual should be
performed only by qualified personnel.
• Before opening the meter, remove test leads from all
circuits to avoid damage to the meter or personal injury.
• To avoid electrical shock, remove test leads from input
jacks before cleaning.
• To avoid false readings that could lead to possible
electric shock, replace the batteries as soon as the low
battery indicator “ ”appears.
• Clean the instrument case with a damp cloth and mild
detergent. Do not use abrasives or chemical solvents.
• Keep in mind the internal capacitors may retain
dangerous voltages even when the instrument is turned
off.
• Remove the batteries if the meter is not going to be used
for an extended period of time.
±(0.3% 5 digits)
Resolution Accuracy
0.01Hz
0.1Hz
1Hz
0.01kHz
0.1kHz
1kHz
0.01MHz
Range
60Hz
600Hz
6kHz
60kHz
600kHz
6MHz
60MHz
In Hertz Mode (Hz)
Note:
Double check the polarity of the battery before replacing.
±(1.5% 5 digits)
Range
Resolution Accuracy
99.99Hz
0.01Hz
999.9Hz
0.1Hz
>10kHz
0.01kHz
Reference only
In Voltage Mode (V)
• Measurement range: 10Hz ~ 10kHz.
• Input range:
≥
0.6V AC rms (
input voltage will increase as
frequency increases
).
• Input impedance: 10MΩ
• Maximum
input
voltage: 600V AC rms.
9.999Hz
0.001kHz
Electrical tester
Electrical tester
49
50