9
KPS-PA30 • Digital clamp meter
ENG
2. SPECIFICATIONS
La précision est garantie pendant 1 anée, 18º C +- 28º C (64ºF et 82ºF) moins
du 75% d’humidité relative.
3.1 General specifications
•
Auto range
•
Overrange protection is provided for all ranges
• Maximum voltage between terminals and earth ground: 600V DC or 600V
rms AC
• Operating altitude: max. 2000 meters (7000 ft.)
• Display: 6000 counts
• Maximum value display: 6000 digits
• Polarity indication: automatic; ‘-‘ for negative polarity
•
Overrange indication: ‘0L’ or ‘-0L’
• Converter Rate: 3 times/sec;
•
Unit indication: function and unit
•
Auto power off time: 15 minute
• Operating power : 1.5V×3 AAA batteries
• Battery low indication: (
) on LCD
• Temperature factor: < 0,1xAccuracy /ºC
•
Operating temperature: 0ºC to 40º C (32ªF to 104ª F)
• Storage temperature: -10º C to 50º C (10º F to 122º F)
• Dimensions: 225x86x33 mm
• Weight: approximate 320 g (including batteries)
3. Accesoires
• Test Leads: Electric Ratings 1000V 10A
1 pair (set)
• Operating manual
1 copy
• 1,5V AAA Battery
3 piece