Network cable tester

ENGLISH

ENG

ENG

KPS SOLUCIONES EN ENERGÍA, S.L.

Parque Empresarial de Argame,

C/Picu Castiellu, Parcelas i-1 a i-3

E-33163 Argame, Morcín

Asturias, España, (Spain)

Anexo A

AT&T258A

8-position Token Ring

EIA/TIA-568B

EIA/TIA-568A

Ethernet 10Base-T

2

1 3 4 5 6 7 8

PR1

PR2

PR4

PR3

PR2 PR1

8

7

6

5

4

3

1 2

2

1 3 4 5 6 7 8

PR1

PR3

PR2

PR4

PR2

PR1

8

7

6

5

4

3

1 2

Anexo 

A

&

A

A

o

e n

 

n

e

x

 

 

o

oo

 

.

-

 

10 BA E-T T

E  RI

 AT&T258A   EIA/TIA568

n

 

en

e

 

een

 

oo

 

n

o

e

 

o

 

e

 

TI- ET

R

  AB E  TE TER

1. RJ45 socket

2. Power indicator

3. Power switch

4. Master unit

5. Cable pairs indicator

6. RJ45 socket

7. BNC socket

8. Remote terminator

9. GND button

10 BNC button

11 BNC indicator

12 BNC socket

Introduction

The multi - network cable tester is widely used for Coaxial Cable ( BNC) , UTP and STP 

Cable it can automatically check for open circuits, shorts, miswires, and reversals.

Caution

Do NOT use on live circuits.

Test for twisted-wire- pair cables (RJ45)

The instrument can be used for 10Base- T, EIA/ TIA- 568A, EIA/ TIA- 568B, AT&T258A, 

and Token Ring Cable.

1. Connect the master unit to one end of the cable to be tested and connect the remote 

    terminator to the other end.

2. Push the power switch to ON, the power indicator will flash to show the power is 

    working properly.

3. The cable pairs indicator on the remote terminator will light one by one. If the indicator is

    lighted GREEN, the corresponding twisted wire pair is OK. If the indicator is lighted RED

    or it is unlighted, the corresponding twisted wire pair is fail.

4. If the cable is shield (STP), you may test the cable’ s shield integrity. Press and hold down

    GND button, the corresponding indicator and GND indicator will light up with all green 

    except the indicator of pair 3&6 is kept off. If GND indicator is lighted red or unlight ed, it‘s

    showing the shield is fail.

Test for coaxial cable ( BNC)

1. Connect the master unit to one end of the coaxial cable to be tested, and connect the 

    remote terminator to the other end.

2. Push the power switch ON, the power indicator will flash to show the power is working 

    properly.

3. After the cable is inserted, the BNC indicator should be kept unlighted. If the BNC 

    indicator is lighted up, then the cable is fail.

4. Press and hold down BNC button which is on the left side of the master unit , the BNC 

    indicator will light up GREEN if the cable is OK. If indicator lights up RED or no light, the

    cable is fail.

Note:

Please make sure the battery has been installed correctly (9 volt 6F22).

ENGLISH

Annex A

Annex B