22
KPS-MT20L • Non-contact voltage detector
ENG
• Polarity Indication: ‘-’indicates negative polarity.
• Overrange Indication: Display ‘OL’
• Sampling Time: approx. 0.4 second
• Unit showing: showing of function and electrical capacity.
• Low Battery Indication: “ ” displayed
• Auto power off time: 15 min.
• Power Supply: 1.5V×2 AAA battery.
• Operating Temperature: 0° to 40°(32°F to 104°F)
• Storage Temperature: -10° to 50°(10°F to 122°F)
• Dimension: 208×38×29 mm
• Weight: approx. 110g (including battery)
3.2 Electrical specifications
Circumstance Temperature: 23±5° Relative Humidity: < 75%
3.2.1 DC Voltage
Range
Resolution
Accuracy
200mV
0,1mV
±( 0,7% of r 2 dígitos )
2V
0,001V
20V
0,01V
200V
0,1V
600V
1V
- Input Impedance: 10MΩ
- Overload Protection: 200mV range: 250V DC or AC rms, 2V-600V ranges:
DC 600V or AC 600V rms.
- Max. Input Voltage: 600V DC