46
KPS-PA50 MINI • Digital clamp meter
ENG
4.16 Measuring capacitance
WARNING
Beware of Electrocution. To avoid electric shock, make sure that the
capacitors have been fully discharged before measuring the capaci-
tance of a capacitor.
• Plug the black test lead into the COM jack and the red test lead into the
INPUT jack.
•
Set the rotary selector to the range position.
•
After fully discharged the capacitor, connect the test leads to the two ends of
the capacitor for measurement.
•
Take the reading on the LCD.
NOTE:
It may take some time (about 10 seconds for the 66mF range) for steady read
-
ings when measuring high capacity.
5. MAINTENANCE
5.1 Replacing the batteries
WARNING
To avoid electric shock, make sure that the test leads have been clearly
move away from the circuit under measurement before opening the
battery cover of the meter.
1) If the sign “
”, appears, it means that the batteries should be replaced.
2) Loosen the fixing screw of the battery cover and remove it.
3) Replace the exhausted batteries with new ones.
4) Put the battery cover back and fix it again to its origin form.
5.2 Replacing test leads
WARNING
The replacement must be test leads in good working condition with the
same or equivalent rating: 1000V 10A.
A test lead must be replaced if the insulation layer has been damaged, e.g. the