22
KPS-PA20 MINI • Digital clamp meter
ENG
400A
0,1A
±(2,5% of r 10 digits)
600A
1A
±(1,5% of r 5 digits)
- Frequency response : 50Hz~60Hz.
- Max Input Current: Full Range×120% and measuring time less than 60 sec
-
onds.
Resistance
Range
Resolution
Accuracy
400Ω
0,1Ω
±(1,2% of r 2 digits)
4Ω
0,001Ω
40kΩ
0,01Ω
400kΩ
0,1Ω
4MΩ
0,001Ω
40MΩ
0,01MΩ
±(2,0% of r 5 digits)
- Overloading protection: 600V DC or 600V AC peak
Diode
Escala
Resolución
Precisión
1mV
Display forward Voltage (Open circuit volt
-
age approximate 1.5V)
- Overloading protection: 600V DC or 600V AC peak
Continuity
Range
Resolution
Accuracy
100mΩ
Less than about ≤60Ω will beep (open
circuit voltage approximate 0.45V
- Overloading protection: 600V DC or 600V AC peak