5-13
3.
-V1 CLEAN BIAS
Use a digital multimeter and set to DC Voltage scale. Connect the meter’s
red probe into the High Voltage Supply –V1, and then connect the black probe
into the Case GND (See Fig.5-10). Turn on CLEAN BIAS under ENGINE
CHECK selection, and then adjust High Voltage Supply VR601 (See Fig.5-11).
Turn VR601 clockwise to increase the voltage. Turn VR601 counterclockwise
to decrease the voltage. Adjust VR601 to –550V.
Fig.5-10
Fig.5-11
Содержание KP3828 Series
Страница 4: ...Chapter 1 Overview ...
Страница 5: ...1 1 1 1 External View External View ...
Страница 17: ...Chapter 2 Principles ...
Страница 40: ...Chapter 3 Installation ...
Страница 47: ...3 7 Step 13 Remove the nut from the drum shaft Fig 3 7 Nut ...
Страница 59: ...3 19 Fig 3 19 AC power terminal box AC cable Breaker Turn on AC power terminal box KMPU board ...
Страница 64: ...Chapter4 Electrical System 4 1 Diagram 4 1 4 2 Electrical Configuration 4 2 4 3 Input Output Signals 4 5 ...
Страница 65: ...Chapter 4 Electrical System ...
Страница 70: ...4 5 4 3 Input Output Signals I O signal block diagram of the KMPU Fig 4 5 KMPU I O Signal Block Diagram ...
Страница 72: ...Chapter 5 Adjustments ...
Страница 88: ...5 16 Fig 5 16 Fig 5 17 ...
Страница 90: ...Chapter 6 Periodic Maintenance ...
Страница 96: ...6 6 6 3 3 Developing Unit Hopper Area Fig 6 3 6 3 4 Cleaning Unit Area Fig 6 4 Cleaning unit ...
Страница 105: ...6 15 2 Wipe the drum surface with the special cloth Fig 6 14 Drum Special cloth ...
Страница 113: ...Chapter 7 Parts Replacement ...
Страница 143: ...7 30 5 Remove the screw from the front bracket and the rear bracket Then remove the lamp Fig 7 48 Screw ...
Страница 145: ...7 32 3 Open the cover remove the screws securing the fuse set and remove the fuse Fig 7 51 Screws Fuse Set ...
Страница 154: ...7 41 7 4 2 DCMTR DRV Board 1 Remove the connectors 2 Remove the screws that secure the DCMTR DRV board Fig 7 64 Screws ...
Страница 172: ...Chapter 8 Troubleshooting ...
Страница 230: ...Appendix I KMPU Circuit Diagram ...