Kozy-World KPH120 Скачать руководство пользователя страница 8

TROUBLESHOOTING

Call 1-800-776-9425 for Technical Assistance

6

Problem

Burner won’t light

Burner won’t stay lit

Emitter glow is uneven

Possible Cause

• Control knob not in IGN/ON position

• Control knob not pressed in while 

in IGN/ON position

• Air in the gas line

• Low gas pressure
• Burner orifice clogged
• Blockage in gas line

Ignitor did not spark:

• Ignitor cable not connected to ignitor
• Igniter electrode positioned wrong
• Ignitor electrode broken
• Ignitor wire pinched or broken

• Control knob not pressed in long 

enough

• Burner flame not touching the 

thermocouple

• Thermocouple damaged or 

connection loose at gas control

• Bad gas valve
• Corrosion of thermocouple contact
• Bad thermocouple
• Tilt switch in trip angle/OFF position

• Heater not level
• Burner tilted

What To Do

• Turn control knob to IGN/ON position

• Press in control knob while in IGN/ON

position

• Purge gas lines and repeat ignition 

operation.

• Replace cylinder
• Clean burner orifice
• Service by a qualified service

technician

• Connect cable to ignitor
• Correct electrode position
• Replace electrode
• Free ignitor cable, if damaged 

replace the assembly

• After burner lights, keep control knob

pressed in for 60 seconds

• Clean pilot assembly

• Tighten connection or replace

thermocouple

Service by qualified service technician

• Clean thermocouple contact

Service by qualified service technician

• Reset tilt switch reset angle/On 

position by tilting heater

• Level heater
• Go to burner removal & installation 

procedure. Straighten burner

Содержание KPH120

Страница 1: ...HE CONSUMER CONSUMER RETAIN THIS MANUAL FOR FUTURE REFERENCE FOR YOUR SAFETY If you smell gas 1 Shut off gas to the appliance 2 Extinguish any open flame 3 If odor continues immediately call your gas...

Страница 2: ...d completely before using Serious injury or death from burns fire explosion and or carbon monoxide poisoning can result from improper use CALIFORNIA PROPOSITION 65 WARNING Fuels used in gas or oil fir...

Страница 3: ...water column is required for the purpose of input adjustment Any replacement regulator must be UL listed The minimum inlet pressure to the regulator from the gas tank is 5 psi and maximum pressure is...

Страница 4: ...STEP 2 STEP 3 STEP 4 STEP 5 22 13 9 36 SELF CONTAINED PROPANE LP GAS SYSTEM The self contained gas system for this mini patio heater is designed to be used with a 16 4 oz Propane gas cylinder disposab...

Страница 5: ...y heating of outdoor areas such as patios spas work areas and outdoor construction sites The installation of your patio heater must conform with local codes or in the absence of local codes with the l...

Страница 6: ...ion and cleaning of the combustion and ventilation air passage ways of the heater burner burner venturi and main burner orifice at least once a year or immediately upon indication of any of the follow...

Страница 7: ...g the gas system is installed by a qualified service person Gas cylinder must be constructed and marked in accordance with specifications of the U S Department of Transportation for Propane Gas Cylind...

Страница 8: ...osion of thermocouple contact Bad thermocouple Tilt switch in trip angle OFF position Heater not level Burner tilted What To Do Turn control knob to IGN ON position Press in control knob while in IGN...

Страница 9: ...C Clip 4PHS001 1 EA 16 Screw 3 EA 17 Countersunk Head Screw 2 EA 18 Screw 3 EA 19 Post 3PHT016 1 EA 20 Nozzle RCM02G 1 EA 21 Nozzle Holder RCD01A 1 EA 22 Stiker 1 EA 23 Tubing Outlet Ass y 3PHT008 1 E...

Страница 10: ...arged for a appliance failures resulting from lack of maintenance This warranty does not cover claims which do not involve defective workmanship or materials THIS LIMITED WARRANTY IS GIVEN TO THE PURC...

Отзывы: