SAFETY  INFORMATION

Continued

11 . T h is  h e at e r  n e e d s   f re s h   air

ventilation  to  run  properly.  This
heater  has  an  Oxygen Depletion
Sensing   (O DS)  safety  sh uto ff
system. The ODS shuts down the
heater  if  not  enough  fresh  air  is
available. See 

Air  for  Combustion

and Ventilation,

 pages 4 through 5.

If  heater  keeps  shutting  off,  see

Tro u b le s h o o ti n g

,     p a g es   1 5

through  17.

12. Do  not  run  heater:

Where   flammable   liquids   or  vapors

are used or stored.

Under  dusty  conditions.

13.Do  not  use  this  heater  to  cook

food or burn paper or other objects.

14. Do not use heater if any part has

been under water. lmmediately call
a  qualified  service  technician  to
inspect  the  room  heater  and  to
replace  any  part  of  the  control
system and any gas control which
has been under water.

LOCAL  CODES

lnstall and  use heater  with care.
Fo llow   all  lo cal  cod es.  In  the
absence of local codes,  use  the
latest  edition  of  The National  Fuel
Gas Code, ANSZ 223.1, also
known as  NFPA  54*.
*Available from:
American  National  Standards
lnstitute,  lnc.
               1430  Broadway

New  York, NY 10018

National  Fire  Protection
Association,  lnc.

Batterymarch  Park
Quincy.  MA  02269

This  heater  is  designed  for
vent-free operation. State and
local  codes  in some  areas
prohibit the use of vent-free
heaters.

UNPACKING

1.  Remove top inner pack.
2.  Tilt carton so that stove is upright.
3.  Remove protective side packaging.
4.  Slide stove out of carton.
5.  Remove protective plastic wrap.
6.  Remove the two screws in the up
     per corners (one on each side),
     then lift and pull forward to remove
     screen.

7.  Remove log set by cutting plastics-
      ties.
8.  Carefully unwrap logs.
9.  Check for any shipping damage. If
     stove or log is damaged, promptly
     inform dealer where you bought
      stove.

PRODUCT FEATURES

SAFETY PILOT

This  heater  has  a  pilot  with  an
Oxygen  Depletion Sensing (ODS)
safety  shutoff  system. The  ODS/
pilot is  a  required  feature  for
vent-free room heaters. The ODS/
pilot shuts off the  heater  if  there
is  not  enough fresh  air.

PIEZO  IGNITION  SYS-

TEM

This  heater  has  a  piezo  ignitor.
This system requires no
matches, batteries,  or  other
sources  to  light heater.

18. To prevent performance
       problems, do not use Propane/
       LP fuel tank of less than 100
       lbs. capacity.

16. Operating heater above eleva
       tions of 4,500 feet could cause
       pilot outage.
17.  Do not operate heater if any log
       is broken. Do not operate
       heater if a log is chipped (dime-
       sized or larger).

15.Turn  off and unplug heater
      and let cool before servicing. Only
      a qualified service person should

     service and repair heater.

QUALIFIED INSTALLING
AGENCY

Installation  and  replacement  of  gas
piping, gas utilization equipment or ac-
cessories and repair and servicing of
equipment shall be performed only by
a qualified agency. The term 

qualified

agency

  means  any  individual,  firm,

corporation, or company that either in
person or through a representative is
engaged in and is responsible for (a)
 the installation, testing, or replacement
of  gas  piping or  (b)  the  connection,
installation, testing, repair, or servicing
of  equipment;  that is  experienced in
such work; that is familiar with all pre

State of Massachusetts:

 

The in-

stallation  must  be made  by  a  li-
censed plumber or gas fitter in the
Commonwealth of Massachusetts.
Sellers of unvented propane or natu-
ral  gas-fired  supplemental  room
heaters shall provide to each pur-
chaser a copy of 527 CMR 30 upon
sale of the unit.
In  the  state  of  Massachusetts,
unvented propane or natural gas-
fired space heaters shall be prohib-
ited in bedrooms and bathrooms.

In the State of Massachusetts the gas
cock must be a 

T

 handle type. The

State of Massachusetts requires that
a flexible appliance connector cannot
exceed three feet in length.

10.Remove legs from inner packing
      below heater.
11. Lay heater down on it

s back and

      attach legs with fasteners
      provided.

cautions required, and that has com-
plied with all the requirement of the
authority having jurisdiction.

PRODUCT   IDENTIFICATION

Figure1- Vent  Free  LP/NG  Gas  Stove

Содержание GSN2221

Страница 1: ...n these instruction for future use WARNING This is an unvented gas fired heater It uses air oxygen from the room in which it is installed Provisions for adequate combustion and ventilation air must be...

Страница 2: ...nning heater Keep the appliance area clear and free from combustible materials gasoline and other flammable vapors and liquids 1 This appliance is only for use with the type of gas indicated on the ra...

Страница 3: ...m heaters The ODS pilot shuts off the heater if there is not enough fresh air PIEZO IGNITION SYS TEM This heater has a piezo ignitor This system requires no matches batteries or other sources to light...

Страница 4: ...ATER LOCATION Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space Space Includes the room in which you will install heater...

Страница 5: ...fined Figure 2 Ventilation Air from Inside Building Example Gas water heater 30 000 Btu Hr Vent free heater 26 000 Btu Hr Total 56 000 Btu Hr WARNING If the area in which the heater may be operated is...

Страница 6: ...ter for proper type heater Figure 4 Minimum Clearance to Wall and Ceiling NOTICE This heater is intended for use as supplemental heat Use this heater along with your primary heating system Do not inst...

Страница 7: ...make sure you have the items listed below l piping check local codes l sealant resistant to propane LP gas l equipment shutoff valve l test gauge connection l sediment trap l tee joint l pipe wrench l...

Страница 8: ...controls If sediment trap is not installed or is installed incorrectly heater may not run properly CAUTION Avoid damage to regulator Hold gas regulator with wrench when connecting into gas piping and...

Страница 9: ...structed Do not modify logs Only use logs supplied with heater IMPORTANT Make sure log does not cover any burner ports see Fig ure 10 Also see log placing instructions Figure 10 Installing Log Set Top...

Страница 10: ...rom the fan to the Black Wire from the Switch Box and the other Black Wire to the White Wire Make sure these wires are clear of the fan Reattach the Back Panel using the 6 screws removed earlier Attac...

Страница 11: ...1 1 Installing Blower Accessory BLOWER ACCESSORY 20 6028 OR 20 6029 Figure 15 F Mounting Blower And Installing Blower Control Housing Figure 14 F Routing Power Cord...

Страница 12: ...12 column 1 If you don t smell gas go to the next step 6 Turn control knob counterclock wise to the PIILOT position Press in control knob for five 5 seconds see Figure 17 l Note You may be running thi...

Страница 13: ...an burning flame Keep these holes clear of dust dirt lint and pet hair Clean these air inlet holes prior to each heating season Blocked air holes will create soot We recommend that you clean the unit...

Страница 14: ...e 74 lbs Shipping 83 lbs For purposes of input adjustment CABINET Air Passageways l Use a vacuum cleaner or pressurized air to clean Exterior l Use a soft cloth dampened with a mild soap and water mix...

Страница 15: ...lot see Cleaning and Maintenance or replace ODS pilot assembly 7 Replace thermocouple 8 Replace control valve POSSIBLECAUSE 1 Ignitor electrode is positioned wrong 2 Ignitor electrode is broken 3 Igni...

Страница 16: ...or partially clogged burner orifice 1 When heated vapors from furniture polish wax carpet cleaners etc turn into a white powder residue REMEDY 1 Clean burner orifice see Cleaning and Maintenance or r...

Страница 17: ...LP gas company 3 Clean ODS pilot 1 Locate and correct all leaks s e e C h e c k i n g G a s Connections 2 Replace control valve 1 Take apart the gas tubing and remove the foreign matter 2 Locate and...

Страница 18: ...2222 GSN2221 K E Y N O PA R T NO D E S C R IP TIO N Q TY N G Q TY LP G S N 3011 G S N 2221 G S N 3013 G S P 3012 G S P 2222 G S P 3014 1 Q L019 01 Le g 1 1 Q L019 02 Le g 1 1 Q L019 01B Le g 1 Q L019...

Страница 19: ...3 GSP3012 GSP2222 GSP3014 1 BL037 02 Log set 1 1 1 1 1 1 2 BL038 02 Log set 1 1 1 1 1 1 3 BL039 02 Log set 1 1 1 1 1 1 4 BL040 02 Log set 1 1 1 1 1 1 5 BL041 02 Log set 1 1 1 1 1 1 6 ND1703X400X4 ODS...