UNPACKING

1.   Remove top inner pack.
2.   Tilt carton so that  fireplace is upright.
3.   Remove protective side packaging.
4.   Slide fireplace out of carton.
5.   Remove protective plastic wrap.
6.   Hold the screen  lift  and  pull
      ing  forward.
7.  Remove log set by cutting plastic

ties.

8.   Carefully unwrap log.
9.   Check for any shipping damage. If

stove or log is damaged, promptly
inform  dealer  where  you  bought
stove.

PRODUCT   IDENTIFICATION

Figure1- Vent  Free  LP/NG  Gas  Stove

WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS

  

Water vapor is a by-product of gas combustion. An unvented room heater produces approximately one(1) ounce

(30ml) of water for every 1,000 BTU

s(.3KW

s)of gas input per hour.

  Unvented room heaters are recommended as supplemental heater(a room). Rather than a primary heat source
(an entire house). In most supplemental heat applications, the water vapor does not creat a problem. In most
applications,the water vapor enhances the low humidity atmosphere experienced during cold weather.The following
steps will help insure that water vapor does not become a problem.
  1.Be sure the heater is a sized properly for the application, including ample combustion air and circulation air.
  2.If high humidity is experienced,dehumidifier may be used to help lower the water vapor content of the air.
  3.Do not use an unvented room heater as the primary heat source.

 lnstall and use heater with care.
F o llo w   all  lo c a l  c o d e s.  In   th e
absence  of  local  codes,  use  the
latest  edition  of  The National  Fuel
Gas Code, ANSI Z223.1, also   known
as  NFPA  54*.
*Available from:
American  National  Standards
lnstitute,  lnc.
                 1430  Broadway

    New  York, NY 10018

National  Fire  Protection
Association,  lnc.

Batterymarch  Park

Quincy.  MA  02269

This  heater  is  designed  for  vent-
free operation. State and  local  codes
in  some  areas  prohibit  the use of
vent-free  heaters.

LOCAL  CODES

4

Содержание GFN4113

Страница 1: ...liance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases GFN4311 GFP4312 GFN4113 GFP4114 GFP4306 GFN4305 GFN4227R GFP4228R W...

Страница 2: ...aterials gasoline and other flammable vapors and liquids 1 This appliance is only for use with the type of gas indicated on the rat ing plate This appliance is not con vertible for use with other gase...

Страница 3: ...connection installation testing repair or servicing of equipment that is experienced in such work that is familiar with all pre cautions required and that has com plied with all the requirement of the...

Страница 4: ...al heat applications the water vapor does not creat a problem In most applications the water vapor enhances the low humidity atmosphere experienced during cold weather The following steps will help in...

Страница 5: ...TION Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space Space Includes the room in which you will install heater plus any...

Страница 6: ...re 2 Ventilation Air from Inside Building Example Gas water heater 30 000 Btu Hr Vent free heater 26 000 Btu Hr Total 56 000 Btu Hr This fresh air would come from an adjoining uncon fined space When v...

Страница 7: ...smoke aromatic candles cleaning fluids oil or kerosene lamps etc in the air exist may discolor walls IMPORTANT Vent free heaters add moisture to the air Although this is beneficial installing heater i...

Страница 8: ...re for purpose of input adjustment NG Models 5 to 10 5 W C Gas supplier provide external regulator for natural gas INSTALLATION Continued WARNING Never connect heater to private non utility gas wells...

Страница 9: ...eater and equipment shutoff valve to gas supply Check reconnected fittings for leaks Pressure Testing Heater Gas Connections 1 Open equipment shutoff valve see Figure 8 Figure 9 Checking Gas Joints CH...

Страница 10: ...ll the logs exactly as instructed Do not modify logs Only use logs supplied wall heater IMPORTANT Make sure log does not cover any burner ports see Figure 10 Figure 10 Installing Log Set FIG 1 FIG 2 S...

Страница 11: ...phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your hand to push in control knob Never use tools If the the appli ance could no...

Страница 12: ...thirty 30 seconds This will allow air to bleed from the gas system 7 With Control Knob pressed in push ignitor button This will light the pilot If needed keep ignitor button until pilot lights MANUAL...

Страница 13: ...n disconne ct two wires free to fan 2 Mark or tag each wire removed for its exact reconnection Remove the four screws from the fan when installing reverse the steps above See Figure 20 and Figure 23 F...

Страница 14: ...the injector holder located at the end of the burner tube again Remove any large particles of dust dirt lint or pet hair with a soft cloth or vacuum cleaner nozzle 5 Blow air into the primary air hol...

Страница 15: ...eater 44 3 16 46 7 8 16 5 8 44 3 16 46 7 8 16 5 8 Carton 44 7 8 51 20 7 8 44 7 8 51 20 7 8 Weight lbs Stove 265 265 Shipping 295 295 GFN4311 GFN4305 GFP4306 GFP4312 Dimensions Inches H W D Heater 45 5...

Страница 16: ...ot unit Spark at ODS pilot but no ignition 1 Gas supply turned off or equip ment shut off valve closed 2 Air in gas lines when installed 3 Depleted gas supply 4 ODS pilot is clogged 5 Gas regulator se...

Страница 17: ...l Your name l Your address l Model and serial numbers of your heater l How heater was malfunctioning l Type of gas used propane LP or NG l Purchase date REPLACEMENT PARTS l Warranty card Usually we w...

Страница 18: ...ER ASSEMBLY 1 ND1703X400 ODS 1 ND1908X400 ODS 1 6 FBB504 ODS INLET TUBE ASSEMBLY 1 1 7 FBB502 INLET TUBE ASSEMBLY 1 1 8 FBB503 OUTLET TUBE ASSEMBLY 1 1 QUALITY KEY NO PART NUMBER DESCRIPTION 5 1 2 3 4...

Страница 19: ...05A5M SIDE PANEL 1 1 5 FB 03A5M BASE 1 1 6 FB 02A5M UPPER PANEL 1 1 7 FHL001 01 BODY TOP COVER 1 1 8 FHL001 02 BODY BOARDING 1 1 9 FHL008 02 BAFFLE 1 1 10 FHL021 022 02 SIDE REFLECTOR 2 2 11 FHL007 02...

Страница 20: ...IDE PANEL 1 1 5 FB 03AM BASE 1 1 6 FB 02AM UPPER PANEL 1 1 7 FHL001 01 BODY TOP COVER 1 1 8 FHL001 02 BODY BOARDING 1 1 9 FhL008 02 BAFFLE 1 1 10 FhL021 022 02 SIDE REFLECTOR 1 1 11 FhL007 02B FIREBOX...

Страница 21: ...LATOR 1 NRV82FB 9 REGULATOR 1 ND4703X400 RHN ODS 1 ND4908X400 RHN ODS 1 NB40 032H BURNER ASSEMBLY 1 NB40 140H BURNER ASSEMBLY 1 HL036 02 INJECTOR 1 HL036 01 INJECTOR 1 9 FBB320RH OUTLET TUBE ASSEMBLY...

Страница 22: ...PANEL 1 1 6 FhL001 01 01 BODY TOP COVER 1 1 7 FhL001 02 01 BODY BOARDING 1 1 8 FhL021 022 02 SIDE REFLECTOR 2 2 9 FhL007 02B FIREBOX FLOOR 1 1 10 FhL001 03 BODY BOTTOM COVER 1 1 11 BL016 07 BLOWER MO...

Отзывы: