OPERATING    HEATER

FOR   YOUR   SAFETY

GFN4227R,GFP4228R Series Models

A.  This  appliance  has  a  pilot  which

must  be  lighted by control system,
W hen  lighting    the    pilot,  follow
t h e s e   i n s t r u c t io n s     e xa c t ly .

B .  B E F O R E   L IG H T IN G   sm ell  all

around    the    appliance    area    for
gas. Be sure to smell  next  to  the
floo r    b ec au se    som e    g as    is
heavier   than  air  and   will  settle
on  the  floor.

WHAT  TO  DO   IF  YOU  SMELL GAS

         

CAUTION:

  Do not  try  to adjust

h eatin g     levels    b y    using     th e
equipment  shutoff  valve.

1.    STOP! Read  the safety information,
      page  2.
2.    Make  sure    equipment    shutoff

valve  is  fully  open.

Note: If operating by remote control,
 you must set the Control Knob on
ELECTRIC position.

Do not set the control knob between
 the locked position, otherwise there
 will be no power to the heater.

Note:

  Please  wait  one  minute  after

shutting  off  fireplace  to  allow  the
electronic  module  to  reset  before
starting again.

Note:

 

To operate your heater the ON/

OFF switch on front of heater must be
 in the ON position. The RED light on
 the front of heater indicates there is
electrical power to your heater when
the ON/OFF switch is in the ON po-
sition. The GREEN light on the fr-
ont of heater indicates the pilot light
is ON. (See Figure 11)

          

  WARNING:

     If    you   do  not

follow  these  instructions  exactly, a
fire  or  explosion  may  result  causing
property  damage, personal injury or
loss  of  life.

    

     NOTICE: 

  During initial  operation

of  new  

fireplace

,  burning logs  will

give  off  a  paper-burning smell. Or-
ange    flame   will   also    be present.
Open  a  window  to  vent  smell. This
will  only  last  a  few hours.

 

   

Do not try to light any appliance.

         Do not touch any electrical switch;
         do not use any phone in your
         building.
         Immediately call your gas sup
         plier from a neighbor

s phone.

         Follow  the gas supplier

s

          instructions.
          If you cannot reach your gas
         supplier, call the fire department.

C.   Use only your hand to  push  in
control  knob. Never use tools. If  the
the appli ance could not operate , don't
try  to repair it, Call a qualified service
technician or gas supplier.Forced or  at-
tempted  re-pair may result   in  a fire or
explosion.

D.    Do  not  use  this  appliance  if  any
part   has   been   under  water. Imme-
diately  call  a  qualified  service  techni-
cian  to inspect   the appliance  and  to
replace any part of  the  control system
and  any gas  control   which  has   been
under  water.

 Function of power ON/OFF swith.

LIGHTING INSTRUCTIONS

Figure 11 - ON/OFF Switch location

OPERATIONS OF

REMOTE TRANSMITTER

1. Install three AAA batteries in the
battery holder. The initial start-up on
the  LCD    is:  SET  TEMP  is  85

°

F,

ROOM TEMP is 85

°

F,  and fan is on

AUTO

 select.

Fig 12 Initial start-up display

 2. When in operation,   point the
remote transmitter to the remote
receiver on the front of fireplace at
a maximum distance of 20 feet
without any obstruction  between
them.

OPERATIONS OF

BURNER

1. Before plugging into the outlet

make sure that the appliance is
connected to the gas supply. Plug
fireplace into a properly grounded
120 Volt, 60Hz, 15 amp outlet. You
will hear a high pitch sound and
power light(red)  on the door will
be lit that indicates that  the
burner is ready to be operated.

2. Point  the remote transmitter to

the burner. Press IGN/OFF button,
the electric spark starts igniting
the pilot and then the burner. Wait
five (5) minutes  to  clear out any
air. If  you smell  gas. STOP!
Please check the gas connection.
The green operation light on the
front of fireplace will be lit when
pilot and burner are on.

Note:

  The main burner  does not

respond  immediately to the set
temperature until about one
minute later.

3. To shut off, press IGN/OFF button

on remote or on front of fireplace.

   

  Note:

 The pilot will also shut off.

11

Содержание GFN4113

Страница 1: ...liance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases GFN4311 GFP4312 GFN4113 GFP4114 GFP4306 GFN4305 GFN4227R GFP4228R W...

Страница 2: ...aterials gasoline and other flammable vapors and liquids 1 This appliance is only for use with the type of gas indicated on the rat ing plate This appliance is not con vertible for use with other gase...

Страница 3: ...connection installation testing repair or servicing of equipment that is experienced in such work that is familiar with all pre cautions required and that has com plied with all the requirement of the...

Страница 4: ...al heat applications the water vapor does not creat a problem In most applications the water vapor enhances the low humidity atmosphere experienced during cold weather The following steps will help in...

Страница 5: ...TION Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space Space Includes the room in which you will install heater plus any...

Страница 6: ...re 2 Ventilation Air from Inside Building Example Gas water heater 30 000 Btu Hr Vent free heater 26 000 Btu Hr Total 56 000 Btu Hr This fresh air would come from an adjoining uncon fined space When v...

Страница 7: ...smoke aromatic candles cleaning fluids oil or kerosene lamps etc in the air exist may discolor walls IMPORTANT Vent free heaters add moisture to the air Although this is beneficial installing heater i...

Страница 8: ...re for purpose of input adjustment NG Models 5 to 10 5 W C Gas supplier provide external regulator for natural gas INSTALLATION Continued WARNING Never connect heater to private non utility gas wells...

Страница 9: ...eater and equipment shutoff valve to gas supply Check reconnected fittings for leaks Pressure Testing Heater Gas Connections 1 Open equipment shutoff valve see Figure 8 Figure 9 Checking Gas Joints CH...

Страница 10: ...ll the logs exactly as instructed Do not modify logs Only use logs supplied wall heater IMPORTANT Make sure log does not cover any burner ports see Figure 10 Figure 10 Installing Log Set FIG 1 FIG 2 S...

Страница 11: ...phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your hand to push in control knob Never use tools If the the appli ance could no...

Страница 12: ...thirty 30 seconds This will allow air to bleed from the gas system 7 With Control Knob pressed in push ignitor button This will light the pilot If needed keep ignitor button until pilot lights MANUAL...

Страница 13: ...n disconne ct two wires free to fan 2 Mark or tag each wire removed for its exact reconnection Remove the four screws from the fan when installing reverse the steps above See Figure 20 and Figure 23 F...

Страница 14: ...the injector holder located at the end of the burner tube again Remove any large particles of dust dirt lint or pet hair with a soft cloth or vacuum cleaner nozzle 5 Blow air into the primary air hol...

Страница 15: ...eater 44 3 16 46 7 8 16 5 8 44 3 16 46 7 8 16 5 8 Carton 44 7 8 51 20 7 8 44 7 8 51 20 7 8 Weight lbs Stove 265 265 Shipping 295 295 GFN4311 GFN4305 GFP4306 GFP4312 Dimensions Inches H W D Heater 45 5...

Страница 16: ...ot unit Spark at ODS pilot but no ignition 1 Gas supply turned off or equip ment shut off valve closed 2 Air in gas lines when installed 3 Depleted gas supply 4 ODS pilot is clogged 5 Gas regulator se...

Страница 17: ...l Your name l Your address l Model and serial numbers of your heater l How heater was malfunctioning l Type of gas used propane LP or NG l Purchase date REPLACEMENT PARTS l Warranty card Usually we w...

Страница 18: ...ER ASSEMBLY 1 ND1703X400 ODS 1 ND1908X400 ODS 1 6 FBB504 ODS INLET TUBE ASSEMBLY 1 1 7 FBB502 INLET TUBE ASSEMBLY 1 1 8 FBB503 OUTLET TUBE ASSEMBLY 1 1 QUALITY KEY NO PART NUMBER DESCRIPTION 5 1 2 3 4...

Страница 19: ...05A5M SIDE PANEL 1 1 5 FB 03A5M BASE 1 1 6 FB 02A5M UPPER PANEL 1 1 7 FHL001 01 BODY TOP COVER 1 1 8 FHL001 02 BODY BOARDING 1 1 9 FHL008 02 BAFFLE 1 1 10 FHL021 022 02 SIDE REFLECTOR 2 2 11 FHL007 02...

Страница 20: ...IDE PANEL 1 1 5 FB 03AM BASE 1 1 6 FB 02AM UPPER PANEL 1 1 7 FHL001 01 BODY TOP COVER 1 1 8 FHL001 02 BODY BOARDING 1 1 9 FhL008 02 BAFFLE 1 1 10 FhL021 022 02 SIDE REFLECTOR 1 1 11 FhL007 02B FIREBOX...

Страница 21: ...LATOR 1 NRV82FB 9 REGULATOR 1 ND4703X400 RHN ODS 1 ND4908X400 RHN ODS 1 NB40 032H BURNER ASSEMBLY 1 NB40 140H BURNER ASSEMBLY 1 HL036 02 INJECTOR 1 HL036 01 INJECTOR 1 9 FBB320RH OUTLET TUBE ASSEMBLY...

Страница 22: ...PANEL 1 1 6 FhL001 01 01 BODY TOP COVER 1 1 7 FhL001 02 01 BODY BOARDING 1 1 8 FhL021 022 02 SIDE REFLECTOR 2 2 9 FhL007 02B FIREBOX FLOOR 1 1 10 FhL001 03 BODY BOTTOM COVER 1 1 11 BL016 07 BLOWER MO...